Special Conditions for Safe Use (X):
1. The apparatus enclosure contains aluminum and is considered to
constitute a potential risk of ignition by impact or friction. Care must
be taken into account during installation and use to prevent impact or
friction.
3.5 Canada
3.5.1 E6 Canada Explosionproof
Certificate
1718395
Standards
CSA Std C22.2 No. 25-1966; CSA Std C22.2 No. 30-M1986;
CAN/CSA-C22.2 No. 94-M91; CSA Std C22.2 No. 142-M1987
Markings
Explosionproof for CL I, DIV 1, GP C, D; CL II, DIV 1, GP E, F, G; CL
III; DIV 1; CL I DIV 2, GP A, B, C, D; Type 4X
3.5.2 I6 Canada Intrinsically Safe
Certificate
1718395
Standards
CSA Std C22.2 No. 25-1966; CSA Std C22.2 No. 30-M1986;
CAN/CSA-C22.2 No. 94-M91; CSA Std C22.2 No. 142-M1987;
CAN/CSA-C22.2 No. 157-92; CSA Std C22.2 No. 213-M1987
Markings
Intrinsically Safe for CL I DIV 1; when installed per 00751-0068;
Type 4X
3.6 Europe
3.6.1 E8 ATEX Flameproof
Certificate
DEMKO 18 ATEX 1958X
Standards
EN 60079-0:2012+A11:2013; EN 60079-1:201
Markings
II 2 G Ex db IIC T5/T6 Gb, T6(-40 °C ≤ T
a
≤ +40 °C), T5(-40
°C ≤ T
a
≤ +70 °C) V
max
= 60 Vdc; I
max
= 50 mA; P
max
=1.5 W
Installation Instructions
1. Only use plugs, adapters, glands, or conduit with a compatible thread
form when closing conduit entries.
2. The 751 may be provided with a 3/4NPT to 1/2NPT thread adapter.
This thread adapter has not been assessed under DEMKO 18 ATEX
1958X. When installing this thread adapter, refer to manufacturer’s
installation instructions
February 2019
Quick Start Guide
Quick Start Guide
13
Summary of Contents for Rosemount 751
Page 1: ...Quick Start Guide 00825 0100 4378 Rev AE February 2019 Rosemount 751 Field Signal Indicator ...
Page 18: ...4 Declaration of Conformity Quick Start Guide February 2019 18 Rosemount 751 ...
Page 19: ...February 2019 Quick Start Guide Quick Start Guide 19 ...
Page 20: ...Quick Start Guide February 2019 20 Rosemount 751 ...
Page 22: ...Quick Start Guide February 2019 22 Rosemount 751 ...
Page 23: ...February 2019 Quick Start Guide Quick Start Guide 23 ...