Installation of Single
Lead Probes in
Non-metallic Tanks
For optimal single lead probe performance in non-metallic tanks the probe
must be mounted with a metal flange, or screwed in to a metal sheet
(d>8 in./200 mm) if the threaded version is used.
Figure 4-3. Mounting in
non-metallic tanks.
Avoid introducing EMI environment near the tank. Installation in metallic tank
is recommended.
Metal flange Ø > 2 in. (DN50)
Metal sheet Ø > 8 in. (200 mm)