Quantum MP User Guide
119
Issue: A4 www.emersonct.com
Parameter
Range(
)
Default(
)
Type
8.01
T24 digital I/O 1 state
{in05, 0.85}
OFF (0) or On (1)
RO
Bit
NC PT
8.02
T25 digital I/O 2 state
{in06, 0.86}
OFF (0) or On (1)
RO
Bit
NC PT
8.03
T26 digital I/O 3 state
{in07, 0.87}
OFF (0) or On (1)
RO
Bit
NC PT
8.04
T27 digital input 4 state
{in08, 0.88}
OFF (0) or On (1)
RO
Bit
NC PT
8.05
T28 digital input 5 state
{in09, 0.89}
OFF (0) or On (1)
RO
Bit
NC PT
8.06
T29 digital input 6 state
{in10, 0.90}
OFF (0) or On (1)
RO
Bit
NC PT
8.07
T51, 52, 53 relay state
OFF (0) or On (1)
RO
Bit
NC PT
8.09
T31 drive enable state
OFF (0) or On (1)
RO
Bit
NC PT
8.10
Enable mode select
0 to 2
0
RW Uni
US
8.11
T24 digital I/O 1 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.12
T25 digital I/O 2 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.13
T26 digital I/O 3 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.14
T27 digital input 4 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.15
T28 digital input 5 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.16
T29 digital input 6 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.17
T51, 52, 53 relay invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.20
Digital I/O read word
0 to 4095
RO Uni
NC PT
8.21
T24 digital I/O 1 source/ destination
Pr
0.00
to
22.99
Pr
10.06
RW Uni DE
PT US
8.22
T25 digital I/O 2 source/ destination
Pr
0.00
to
22.99
Pr
0.00
RW Uni DE
PT US
8.23
T26 digital I/O 3 source/ destination
Pr
0.00
to
22.99
Pr
0.00
RW Uni DE
PT US
8.24
T27 digital input 4 destination
Pr
0.00
to
22.99
Pr
0.00
RW Uni DE
PT US
8.25
T28 digital input 5 destination
Pr
0.00
to
22.99
Pr
1.41
RW Uni DE
PT US
8.26
T29 digital input 6 destination
Pr
0.00
to
22.99
Pr
0.00
RW Uni DE
PT US
8.27
T51, 52, 53 relay source
Pr
0.00
to
22.99
Pr
10.01
RW Uni
PT US
8.29
I/O polarity select
2
1
RW Uni
PT US
8.30
Open collector output
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.31
T24 digital I/O 1 output select
OFF (0) or On (1)
On (1)
RW Bit
US
8.32
T25 digital I/O 2 output select
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.33
T26 digital I/O 3 output select
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.40
T61, 62, 63 relay state
OFF (0) or On (1)
RO
Bit
NC PT
8.41
Start button state
OFF (0) or On (1)
RO
Bit
NC PT
8.42
Forward/reverse button state
OFF (0) or On (1)
RO
Bit
NC PT
8.48
24V input state
OFF (0) or On (1)
RO
Bit
NC PT
8.50
T61, 62, 63 relay invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.52
Toggle enable
OFF (0) or On (1)
OFF (0)
RW Bit
US
8.60
T61, 62, 63 relay destination
Pr
0.00
to
22.99
Pr
6.55
RW Uni DE
PT US
8.61
Start button destination
Pr
0.00
to
22.99
Pr
0.00
RW Uni DE
PT US
8.62
Forward/reverse button destination
Pr
0.00
to
22.99
Pr
0.00
RW Uni DE
PT US
RW
Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save