
Quantum MP User Guide
111
Issue: A4 www.emersonct.com
Parameter
Range(
)
Default(
)
Type
5.01
Armature firing angle
0 to 175.0 °
RO Uni FI NC PT
5.02
Armature voltage
{di10, 0.45}
±ARMATURE_VOLTAGE_MAX V
RO
Bi
FI NC PT
5.03
Output power
±POWER_MAX kW
RO
Bi
FI NC PT
5.04
Estimated speed
±10,000.0 rpm
RO
Bi
FI NC PT
5.05
Line voltage
0 to 1000V rms AC
RO Uni FI NC PT
5.06
Machine armature voltage
±ARMATURE_VOLTAGE_MAX V
RO
Bi
Fl
NC PT
5.07
Motor rated current
{SE07, 0.28}
0 to RATED_CURRENT_MAX A
RATED_CURRENT_MAX
RW Uni
RA
US
5.08
Base speed
{SE08, 0.29}
0.0 to 10,000.0 rpm
1,000.0
RW Uni
US
5.09
Armature rated voltage
{SE06, 0.27}
0 to ARMATURE_VOLTAGE_MAX Vdc
For 480V drive: 440 Eur 500 USA
For 575V drive: 630 Eur 630 USA
For 690V drive: 760 Eur 760 USA
RW Uni
RA
US
5.10
Direct firing angle
0 to 165.0 °
165.0
RW Uni
5.11
Direct firing angle enable
OFF (0) or On (1)
OFF (0)
RW Uni
US
5.12
Autotune
{SE13, 0.34}
0 to 3
0
RW Uni
NC
5.13
Continuous Back End Stop
0 to 165.0 °
165.0
RW Uni
US
5.14
Armature voltage select
OFF (0) or On (1)
OFF (0)
RW Bit
US
5.15
Motor constant
0 to 100.0%
50.0%
RW Uni
US
5.16
DC contactor
OFF (0) or On (1)
ON (1)
RW Bit
US
5.21
Quadrant 1 Enable
0 to 1
1
RW Uni
US
5.22
Quadrant 2 Enable
0 to 1
1
RW Uni
RA
US
5.23
Quadrant 3 Enable
0 to QUADRANT_MAX
1
RW Uni
US
5.24
Quadrant 4 Enable
0 to QUADRANT_MAX
1
RW Uni
RA
US
5.25
Disable adaptive control
OFF (0) or On (1)
OFF (0)
RW Bit
US
5.26
Continuous auto tune
OFF (0) or On (1)
OFF (0)
RW Bit
US
5.28
Field weakening compensation disable
OFF (0) or On (1)
Eur: 0, USA: 1
RW Bit
US
5.29
Motor saturation breakpoint 1
0 to 100% of rated flux
50
RW Uni
US
5.30
Motor saturation breakpoint 2
0 to 100% of rated flux
75
RW Uni
US
5.32
Motor torque per amp
0.000 to 50.000 NmA
-1
RO Uni
5.43
Armature mode
0 to 6
0
RW Txt
US
5.45
Bridge request output
0 to 1
RW Bit
5.46
Slave bridge request status
0 to 1
RW Bit
5.47
RW Bit
5.48
RW Bit
5.50
Security unlock
0 to 999
RW Uni
NC PT
5.52
IR drop
±ARMATURE_VOLTAGE_MAX Vdc
RO
Bi
FI NC PT
5.53
Back emf
±ARMATURE_VOLTAGE_MAX Vdc
RO
Bi
FI NC PT
5.54
Flux feedback
±150%
RO
Bi
FI NC PT
5.55
Flux demand
±120%
RW
Bi
FI NC PT
5.56
Field current feedback
{di09, 0.44}
±50.00 A
RO
Bi
FI NC PT
5.57
Percentage voltage demand
±150.0%
RO
Bi
FI NC PT
5.58
Field firing angle
0 to 180.0 °
RO Uni FI NC PT
5.59
Back emf set point
0 to ARMATURE_VOLTAGE_MAX Vdc
For 480V Drive: 440 Eur 500 USA
RW Uni
US
5.61
Armature Resistance
0 to 6.0000
0.0000
RW Uni
US
5.62
Spill over loop P gain
0 to 300.00
0.40
RW Uni
US
5.63
Spill over loop I gain
0 to 300.00
5.00
RW Uni
US
5.65
Enable economy timeout
0 to 1
Eur: 0, USA: 1
RW Bit
US
5.67
Field economy level
0 to 120.0%
25.0%
RW Uni
US
5.68
Maximum flux
0 to 120.0%
100.0%
RW Uni
US
5.69
Minimum flux
0 to 120.0%
50.0%
RW Uni
US
5.70
Rated field current
{SE10, 0.31}
0 to FIELD_CURRENT_SET_MAX
Size 1-Eur: 2A, USA: 8A
RW Uni
RA PT US
5.71
Flux loop P gain
0 to 300.00
3.00
RW Uni
PT US
5.72
Flux loop I gain
0 to 300.00
60.00
RW Uni
US
5.73
Rated field voltage
{SE11, 0.32}
0 to 500.0 Vdc
Eur: 360, USA: 300
RW Uni
US
5.74
Rated field compensation factor
0 to 100%
100%
RW Uni
PT US
5.75
Field voltage mode select
OFF (0) or On (1)
Eur: 0, USA: 1
RW Bit
US
5.76
Auxiliary supply
0 to 550 rms Vac
RO Uni FI NC PT
5.77
Enable field control
{SE12, 0.33}
OFF (0) or On (1)
OFF (0)
RW Txt
US
5.78
Field mode
IntrnL (0), EtrnL (1), E FULL (2)
IntrnL (0)
RW Txt
US
5.79
Economy active
OFF (0) or On (1)
RO
Bit
5.80
Economy level select
OFF (0) or On (1)
OFF (0)
RW Bit
US
5.81
Field thermal time constant
0 to 3000.0
24.0
RW Uni
US
5.82
Field overload accumulator
0 to 100.0%
RO Uni
NC PT
5.83
Field reversal enable
0 to ONLY_2_QUADRANT
0
RW Uni
RA
US
5.84
Field flux threshold
0 to 100%
75%
RW Uni
US
5.85
Flux demand invert
0 to 1
RO
Bit
NC PT
5.86
Speed error invert
0 to 1
RO
Bit
NC PT