PACSystems Ethernet Switch SLM080 User Manual
Section 8
GFK-3125A
Jan 2020
Technical Specifications
99
Warning / Monitoring System
Relay output for fault event alarming
Syslog server / client to record and view events
Include SMTP for event warning notification via
email Event selection support
RS-232 Serial Console Port
RS-232 in RJ45 connector with console cable. 9600bps, 8, N, 1
LED Indicators
Power Iindicator
Green : Power LED x 3
R.M. Indicator
Green : Indicate system operated in Redundant Ring Master
mode
Redundant Ring Indicator
Green : Indicate system operated in Redundant Ring mode
Fault Indicator
Amber : Indicate unexpected event occurred
10/100Base-T(X) RJ45 P o r t
Indicator
Green for port Link/Act . Amber for Duplex/Collision
Fault Contact
Relay
Relay output to carry capacity of 1A at 24VDC
Power
Redundant Input Power
Triple DC inputs. 12~48VDC on 7-pin terminal
block,
12~45VDC on power jack
Power Consumption (Typ.)
9 Watts
Overload Current Protection
Present
Reverse Polarity Protection
Present on terminal block
Physical Characteristic
Enclosure
IP-30
Dimension (W x D x H)
52(W)x106.1(D)x144.3(H) mm (2.05x4.18x5.68 inch.)
Weight (g)
730 g
Environmental
Storage Temperature
-40 to 85oC (-40 to 185oF)
Operating Temperature
-40 to 70oC (-40 to 158oF)
Operating Humidity
5% to 95% Non-condensing
Regulatory approvals
EMI
FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4
(EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS),
EN61000-4-8, EN61000-4-11
Shock
IEC60068-2-27
Free Fall
IEC60068-2-32
Vibration
IEC60068-2-6
Warranty