39
Distance (feet)
AWG #20
AWG #18
AWG #16
AWG #14
AWG #12
AWG #10
AWG #8
6500
66.00
41.50
26.10
16.40
10.30
6.50
4.08
7000
71.10
44.70
28.10
17.70
11.10
7.00
4.40
7500
76.10
47.90
30.10
19.00
12.00
7.49
4.71
8000
81.20
51.10
23.10
20.20
12.70
7.99
5.03
9000
91.40
57.50
36.10
22.70
14.30
8.99
5.65
10000
102.00
63.90
40.20
25.30
15.90
9.99
6.28
Resistance shown is one way. This figure should be doubled when determining closed loop resistance.