Operation
MITX-430/MITX-440-DVI-2E Installation and Use Guide (6806800K37B
)
98
5.5.2.4
DXE Status Codes
Table 5-35 DXE Status Codes
Status Code
Description
0x60
DXE Core is started.
0x61
NVRAM initialization.
0x62
Installation of the South Bridge Runtime Services.
0x63
CPU DXE initialization is started.
0x64
CPU DXE initialization (CPU module specific).
0x65
CPU DXE initialization (CPU module specific).
0x66
CPU DXE initialization (CPU module specific).
0x67
CPU DXE initialization (CPU module specific).
0x68
PCI host bridge initialization.
0x69
North Bridge DXE initialization is started.
0x6A
North Bridge DXE SMM initialization is started.
0x6B
North Bridge DXE initialization (North Bridge module specific).
0x6C
North Bridge DXE initialization (North Bridge module specific).
0x6D
North Bridge DXE initialization (North Bridge module specific).
0x6E
North Bridge DXE initialization (North Bridge module specific).
0x6F
North Bridge DXE initialization (North Bridge module specific).
0x70
South Bridge DXE initialization is started.
0x71
South Bridge DXE SMM initialization is started.
0x72
South Bridge devices initialization.
0x73
South Bridge DXE initialization (South Bridge module specific).
0x74
South Bridge DXE initialization (South Bridge module specific).
0x75
South Bridge DXE initialization (South Bridge module specific).
0x76
South Bridge DXE initialization (South Bridge module specific).
0x77
South Bridge DXE initialization (South Bridge module specific).
Summary of Contents for MITX-430
Page 10: ...MITX 430 MITX 440 DVI 2E Installation and Use Guide 6806800K37B 10 List of Tables ...
Page 12: ...MITX 430 MITX 440 DVI 2E Installation and Use Guide 6806800K37B 12 List of Figures ...
Page 30: ...Introduction MITX 430 MITX 440 DVI 2E Installation and Use Guide 6806800K37B 30 ...
Page 104: ...Operation MITX 430 MITX 440 DVI 2E Installation and Use Guide 6806800K37B 104 ...
Page 132: ...MITX 430 MITX 440 DVI 2E Installation and Use Guide 6806800K37B Safety Notes 132 ...
Page 159: ......