94
Micro Motion Series 1000 and Series 2000 Transmitters
Pressure Compensation, Temperature Compensation, and Polling
Figure 9-5
Configuring polling with ProLink II
Polling for pressure
Set
External temperature
to 32 °F (0 °C)
Apply
Polled variables
Specify
Polling control
(1)
Enter
HART tag
of external device
Specify
Process variable
Polled variable 1
Specify
Polling control
(2)
Enter
HART tag
of external device
Specify
Process variable
Polled variable 2
Apply
Apply
Done
Done
Apply
Apply
Polling for temperature
ProLink >
Configuration >
ProLink >
Configuration >
Temperature
(1) Choose Primary if the external
device will probably be accessed
by another device acting as a
secondary master (e.g., a
Communicator). Choose
Secondary if the external device
will probably be accessed by
another device acting as a
primary master.
(2) If you are configuring both Polled
Variable 1 and Polled Variable 2,
use the same Polling Control
setting for both. If you do not, Poll
as Primary will be used for both
devices.
Summary of Contents for MICRO MOTION 1500
Page 10: ...viii Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 18: ...8 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 24: ...14 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 38: ...28 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 44: ...34 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 64: ...54 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 74: ...64 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 106: ...96 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 172: ...162 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 178: ...168 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 190: ...180 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 268: ...258 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 280: ...270 Micro Motion Series 1000 and Series 2000 Transmitters ...
Page 281: ......