background image

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all
defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.

What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and
accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO
COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.

What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other
accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and
no replacement can be provided, Emerson will refund the actual purchase price of your fan. WE WILL SHIP THE
REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OR
REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO.

How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE.
KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest
authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air

Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model
numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized

service center.

You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service
center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not
be responsible for any such damage.

What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover
any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear

and tear.

Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided
when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or
oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of
Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND
EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL
DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use.
Consequential damages include but are not limited to the cost of repairing or replacing other property which was
damaged if this product does not work properly.

How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or
limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which
vary from state to state.

Part No. F40BP72830004

Printed in China  08/06

Form No. BP7283-4

Air Comfort Products

DIVISION OF EMERSON ELECTRIC CO.

8100 W. Florissant ¥ St. Louis, MO 63136

BP7283, High Country, KF160  7/31/06  10:54 AM  Page 16

Summary of Contents for HIGH COUNTRY KF160OI01

Page 1: ... No BP7283 4 U L Model No KF160 READ AND SAVE THESE INSTRUCTIONS KF160OI01 Olde Iron with Washed Oak Honey Maple Blades HIGH COUNTRY Ceiling Fan Owner s Manual Emerson Fans Designed by Model Number BP7283 High Country KF160 7 31 06 10 54 AM Page 1 ...

Page 2: ...ort of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The longer downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling The shorter downrod must be used for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent a...

Page 3: ...ury or property damage WARNING a Fan motor housing assembly b One upper glass c One ceiling cover d One decorative cover e Five fan blades f Five blade flanges g One hanger bracket h One hanger ball downrod assembly i One 3 1 2 downrod j One decorative cap k One finial nut l One lower glass m One decorative scroll assembly n One light fitter adapter o One light fitter assembly p One remote control...

Page 4: ...ght push buttons turn the lights on and off and controls the light intensities The red indicator light will illuminate while any button is pressed indicating that the battery is good Preset Memory Feature Your remote control receiver is equipped with a preset memory feature The receiv er will remember the light intensity and fan speed when the light and fan are turned off from the wall switch When...

Page 5: ...se or circuit breaker box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING How to Assemble Your Ceiling Fan 1 Place the motor housing assembly on a flat surface with the top of the motor facing upwards Place the upper glass over the motor housing assembly aligning the...

Page 6: ...pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull up on the downrod to make sure the clevis pin is properly installed 4 Remove and discard the three shipping retainers securing the motor hub in the motor housing NOTE Take care not to scratch the fan housing when installing the b...

Page 7: ...l 12 Place the ceiling cover over the down rod Then reinstall the hanger ball Figure 8 on the downrod as follows Route the four 80 motor leads through the hanger ball and slide the hanger ball over the downrod Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up DOWNROD MOTOR COUPL...

Page 8: ...e 10 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires between the han...

Page 9: ...nd connect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor this may be a bare wire or a wire with green insulation b Securely connect the supply white neutral wire to the receiver white AC IN N wire c Securely connect the supply black wire hot wire to...

Page 10: ...NAL SW115 WALL CONTROL BLACK BLACK WHITE BLACK BLACK WHITE HANGER BALL GREEN WIRE GROUND FROM HANGER BALL AND HANGER BRACKET TWO CONDUCTOR CABLE WITH GROUND BLACK HOT WHITE GROUND TO 120 VOLT SUPPLY WHITE BLUE BLUE ORANGE ORANGE WHITE Figure 13 3 Push the wires and connectors up into the outlet box while inserting the receiv er fully into the hanger bracket Position the antenna wire on top of the ...

Page 11: ... system 8 Connect the white wire from the light fitter to the white wire from the motor Figure 16 Connect the black wire from the light fitter to the black wire from the motor Make sure connectors are fully engaged 9 Position the adapter light fitter assem bly over the adapter plate and secure using three 8 32 x 12mm pan head screws Figure 17 BLACK WIRE WHITE WIRE LIGHT FITTER ADAPTER PLATE ADAPTE...

Page 12: ...he downlight on press and release the DN button The light will turn on at the light intensity previously selected 6 To turn the uplight on press and release the UP button The light will turn on at the light intensity previously selected 7 To vary the intensity of the light hold the DN or UP button down until the desired light intensity is reached then release the button Red light should turn on wh...

Page 13: ...ference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television recept...

Page 14: ...ing against each other or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Screws holding blades to 4 Tighten screws securely flanges are loose 5 Loose screws in motor housing 5 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling is 1 Raise coupling cover and tighten excessively not tightened ...

Page 15: ...635 6 23 Flange Set full set for one fan 762723 OI 24 Harness Assembly Wiring 762704 25 Adapter Fitter 762703 OI 26 Fitter Assembly Light 763206 27 Glass Lower 762702 28 Glass Upper 762701 29 Cap Decorative 762706 OI 30 Nut Finial 762707 OI 31 Downrod 3 1 2 761631 42 32 Receiver Remote Control 762670 2 33 Transmitter Remote Control 762402 Owner s Manual BP7283 4 Before discarding packaging materia...

Page 16: ...actory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized ...

Reviews: