Specifications

Maximum Inlet Pressure: 

400 psig (27,6 bar)

(1)

Operation  

 

CAUTION

The Type N550 handle and shaft may    

break if the valve is forced open against  

the gas flow and before pressure is  

 

equalized on each side of the main 

valve disk.  

 

To Open a Closed Valve:  

 

Close a shutoff valve downstream of the Type N550.  

Pull the Type N550 handle counterclockwise.  There 

will be an opening as inlet pressure helps hold the 

valve disk closed against the seat.  The initial opening 

force on the handle opens a pilot valve in the main 

valve disk, permitting pressure to build-up downstream.  

When differential pressure across the main disk has 

been reduced, the Type N550 can be opened without 

further difficulty by continuing to lift the handle to the 

open position.  When the handle is fully open (handle 

perpendicular to the pipe) the latch engages to hold  

the valve open.  

CAUTION

Because the valve is spring closed 

(aided by pressure), the handle can snap 

down with considerable force when 

closing.  Keep hands and fingers away 

from the handle as it closes.  

 

To Close an Open Valve:  

 

Pushing the handle down (handle parallel to the pipe) 

will close the valve.  

 

From a remote location, pulling on the remote cable or 

exhausting pneumatic pressure from the Type P327D 

will retract the plunger allowing the Type N550 to close.  

If emergency conditions cause the fusible element to 

reach a temperature of 212°F (100°C), the element, 

which attaches the handle to the shaft, pulls apart and  

allows the valve to close.  

 

Installation  

 

Shutoff Direction   

The valves shall be installed in the fixed piping 

between a storage tank and the transfer hose 

connection at the truck or tank car loading/unloading 

area.  They can be placed in a line used either for 

filling or withdrawing from the storage tank (or both).  

The valve shall be installed to shutoff flow from the 

tank towards the hose, enabling the valve to control 

product loss in case of a hose break.    

!

WARNING

The Type N550 valves are spring closed 

(aided by pressure) and shutoff flow in 

one direction only.  THE NAMEPLATE 

FLOW ARROW SHOWS FLOW 

DIRECTION FOR VALVE SHUTOFF 

(see Figure 6).  The arrow shall point 

to the hose connection.  Improper flow 

direction will not shutoff flow through 

the line.    

When installed in horizontal piping, install with the  

nameplate up.  The valve can be installed in vertical  

piping with the flow arrow pointing to the desired flow  

direction for valve shutoff.  In some cases the normal 

flow through the valve may be opposite the shutoff 

direction (like a back check valve).  

 

Bulkhead Protection    

The valve should be installed near the hose 

connection, but shall be positioned so that any undue 

strain resulting from a hose pull cannot shear the valve 

or its inlet piping from the storage area piping.  The 

piping shall always be firmly supported and anchored 

to be sure of meeting the requirement.    
One preferred method of installation is shown in 

Figure 2 where the pipe connection to the valve and 

to the hose coupling is securely anchored in a 

solid bulkhead.   

TYPE

BODY SIZES, NPS*

PROPANE FLOW AT 2 PSI (0,14 bar) 

DIFFERENTIAL, GPM (l/min)

N550-10

1-1/4 FNPT

  75 (284)

N550-16

2 FNPT

115 (435)

N550-24

3 FNPT

  275 (1041)

Temperature Capabilities: 

-40° to 212°F (-40° to 100°C)

  1.  The pressure limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.

  *Nominal Pipe Size

2

Type N550

Summary of Contents for Fisher Snappy Joe N550

Page 1: ...ntended for in line use on LP Gas or Anhydrous Ammonia NH3 service The valves may be installed on both ends of transfer hoses where the hose connects the bulk plant piping to the bobtail transport or tank car They provide a quick way of shutting off gas flow in the event of a hose rupture and meet the requirements for such service when correctly installed with a remote release and proper piping su...

Page 2: ...en a storage tank and the transfer hose connection at the truck or tank car loading unloading area They can be placed in a line used either for filling or withdrawing from the storage tank or both The valve shall be installed to shutoff flow from the tank towards the hose enabling the valve to control product loss in case of a hose break WARNING The Type N550 valves are spring closed aided by pres...

Page 3: ...de enough pull on the hose connection to cause a break in the system That break must not occur between the Type N550 and the storage tank Fusible Element Location A fusible element that will close the Type N550 shall be located within five feet of the hose connection If the Type N550 is placed within five feet of the hose connection this requirement is met If not an additional fusible element must...

Page 4: ... of the cable housing and cable housing nut fit into the conical end of the latch block Pulling the excess inner cable through the housing from the remote release end will hold the housing in the latch block 10 Mount the remote release cylinder assembly to a suitable support at the remote release location 7 16 inch 11 mm diameter mounting hole but do not tighten the mounting nut 11 At the remote r...

Page 5: ...e Type P327D see Figure 4 1 Close the Type N550 valve Handle is parallel to the pipe 2 Remove the long end of the external spring from under the latch block DO NOT REMOVE SPRING FROM HANDLE 3 Remove latch bolt s Older valves will have 2 bolts DISCARD CABLE LATCH BLOCK 4 Use a 5 32 inch 4 mm Allen head wrench to screw 1 4 inch 6 4 mm long bolt into bottom hole 5 Tighten until bolt head seats firmly...

Page 6: ... connection When the hose stretches more than the amount of slack left in the cable the tightening cable will pull the lever down and close the Type N550 valve CAUTION Possible hand and finger pinch point between closing Type N550 handle and latch block Handle closes quickly and with extreme force Keep hands and fingers away from handle as it closes 10 Test the remote release and Type N550 operati...

Page 7: ...epaired in the field However due to the special fire resistant seals and assembly techniques repairs should be done only by trained personnel If repair should become necessary contact your local LP Gas Equipment Distributor for information and assistance Only parts manufactured by Emerson Process Management Regulator Technologies Inc should be used for the repair of Fisher Type N550 Valves Be sure...

Page 8: ...eel T12851T0012 29 Washer Carbon steel 2 Required T1207524082 30 Packing Stack T12854T0012 31 Follower 174 Stainless steel T12841T0012 32 Retainer Steel T20674T0012 33 Bolt Stainless steel 2 Required T12499T0012 34 Bushing T12551T0012 35 Washer Nylon PA T12781T0012 36 Latch Block Aluminum T13800T0012 37 Spring 302 Stainless steel T13877T0012 38 Plunger Polyester T12846T0012 39 Cable T12849T0012 40...