background image

Optional Motion Release Cable  

 

With either the cable or pneumatic remote release 

hook-ups, it is possible to connect an additional cable  

from the Type N550’s operating handle to the truck 

along the transfer hose(s).  This cable would close 

the valve if the hose(s) is stretched (driver does not 

disconnect) beyond a preselected limit.  The hook-up 

does not affect the normal operation of the valve. 

Motion Release Cable Installation    

  1.  Connect a suitable release cable such as stainless 

steel aircraft cable to a standard “S” hook.  

Attach the “S” hook to the Type N550 handle as 

shown in Figure 5.

  2.  The cable should run through the bulkhead just 

below and to the side of the pipe.  The cable 

should be in line with the operating lever, refer 

to Figure 5.  

 

  3.  Leave enough slack in the cable to allow the  

       Type N550 lever to move freely but not close  

       during normal hose movement or hook-up.    
  4.  Run the cable along the hose.  Tape or secure it to 

the hose.  Fasten the cable securely to the “truck” 

end hose connection.  

 

       When the hose stretches more than the amount of     

       slack left in the cable, the tightening cable will pull the  

       lever down and close the Type N550 valve.  

CAUTION

Possible hand and finger pinch point  

between closing Type N550 handle and 

latch block.  Handle closes quickly and 

with extreme force.  Keep hands and 

fingers away from handle as it closes.    

  10.   Test the remote release and Type N550    

         operation.  Rotate handle counter clockwise  

         to open valve.  Valve must stay open.  

HANDLE     

         AND VALVE MUST QUICKLY “SNAP”               

         CLOSED

 when (a) air pressure is exhausted  

         from Type P327D pneumatic remote release,  

         and (b) the handle is pushed closed from the  

         open position. 

 

!

WARNING

 

All open Type N550 Emergency Valve(s)   

attached to the remote pneumatic  

 

release system must properly close  

 

when air pressure is exhausted from the 

system.  Remote release controls must   

quickly exhaust pressure from the 

supply line to close emergency valves.    

Figure 5. 

 Motion Release Cable Installation (Optional)

TO TRUCK

BULKHEAD

HOSE CONNECTION

12 (305) 

OR MORE

FIXED PIPING

NAMEPLATE UP

EMERGENCY SHUTOFF

VALVE TYPE N550

REMOTE ACTIVATION METHOD, 

CABLE OR PNEUMATIC, 

ATTACHMENT LOCATION

1 (25)

“S” HOOK

CABLE

T20995

INCHES 

(mm)

6

Type N550

Summary of Contents for Fisher Snappy Joe N550

Page 1: ...ntended for in line use on LP Gas or Anhydrous Ammonia NH3 service The valves may be installed on both ends of transfer hoses where the hose connects the bulk plant piping to the bobtail transport or tank car They provide a quick way of shutting off gas flow in the event of a hose rupture and meet the requirements for such service when correctly installed with a remote release and proper piping su...

Page 2: ...en a storage tank and the transfer hose connection at the truck or tank car loading unloading area They can be placed in a line used either for filling or withdrawing from the storage tank or both The valve shall be installed to shutoff flow from the tank towards the hose enabling the valve to control product loss in case of a hose break WARNING The Type N550 valves are spring closed aided by pres...

Page 3: ...de enough pull on the hose connection to cause a break in the system That break must not occur between the Type N550 and the storage tank Fusible Element Location A fusible element that will close the Type N550 shall be located within five feet of the hose connection If the Type N550 is placed within five feet of the hose connection this requirement is met If not an additional fusible element must...

Page 4: ... of the cable housing and cable housing nut fit into the conical end of the latch block Pulling the excess inner cable through the housing from the remote release end will hold the housing in the latch block 10 Mount the remote release cylinder assembly to a suitable support at the remote release location 7 16 inch 11 mm diameter mounting hole but do not tighten the mounting nut 11 At the remote r...

Page 5: ...e Type P327D see Figure 4 1 Close the Type N550 valve Handle is parallel to the pipe 2 Remove the long end of the external spring from under the latch block DO NOT REMOVE SPRING FROM HANDLE 3 Remove latch bolt s Older valves will have 2 bolts DISCARD CABLE LATCH BLOCK 4 Use a 5 32 inch 4 mm Allen head wrench to screw 1 4 inch 6 4 mm long bolt into bottom hole 5 Tighten until bolt head seats firmly...

Page 6: ... connection When the hose stretches more than the amount of slack left in the cable the tightening cable will pull the lever down and close the Type N550 valve CAUTION Possible hand and finger pinch point between closing Type N550 handle and latch block Handle closes quickly and with extreme force Keep hands and fingers away from handle as it closes 10 Test the remote release and Type N550 operati...

Page 7: ...epaired in the field However due to the special fire resistant seals and assembly techniques repairs should be done only by trained personnel If repair should become necessary contact your local LP Gas Equipment Distributor for information and assistance Only parts manufactured by Emerson Process Management Regulator Technologies Inc should be used for the repair of Fisher Type N550 Valves Be sure...

Page 8: ...eel T12851T0012 29 Washer Carbon steel 2 Required T1207524082 30 Packing Stack T12854T0012 31 Follower 174 Stainless steel T12841T0012 32 Retainer Steel T20674T0012 33 Bolt Stainless steel 2 Required T12499T0012 34 Bushing T12551T0012 35 Washer Nylon PA T12781T0012 36 Latch Block Aluminum T13800T0012 37 Spring 302 Stainless steel T13877T0012 38 Plunger Polyester T12846T0012 39 Cable T12849T0012 40...

Reviews: