CS200 Series

5

INLET PRESSURE

OUTLET PRESSURE

ATMOSPHERIC PRESSURE

Figure 3.

  CS200 Series with Secondary Seat Protection

4

  CP200 Series with Secondary Seat

TM

 Protection

CONTROL SPRING

 

RELIEF V LVE STEM

VALVE STEM

SECONDARY SEAT DETAIL

SECONDARY SEAT™ DETAILED VIEW

NORMAL OPERATION

NORMAL LOCKUP

DEBRIS OBSTRUCTING

LOCKUP

SECONDARY SEAT

LOCKUP

TYPE CS206 

SECONDARY SEAT WITH 

METAL TO METAL BLEED

METALLIC SECONDARY 

ORIFICE SEATING SURFACE

PRIMARY DISK

SECONDARY SEATING 

SURFACE

PRIMARY ORIFICE 

SEATING SURFACE

ELASTOMERIC SECONDARY 

SEATING SURFACE

Type CS206 Secondary Seat Protection 

with Bleed

The Type CS206 provides small bleed to the downstream 

system as an indication that the Secondary Seat is 

providing lockup.  In the event that the primary orifice 

and disk cannot provide lockup, the secondary seating 

surface will move into contact with a metal disk.  This 

metal to metal interface will allow a small amount of gas 

to bleed downstream thereby increasing outlet pressure 

until the Internal relief valve begins to discharge gas 

to the atmosphere.  The odor of this discharged gas 

provides an indication that the regulator is relying on 

the Secondary Seat for overpressure protection.   See 

Table 5 for the Downstream Pressure Build-up of the 

Internal relief acting in conjunction with the Type CS206 

Secondary Seat Assembly.

Types CS205 and CS206 Secondary Seat 

Protection Limitations

CAUTION

Overpressure conditions can occur 

in the downstream piping when the 

Secondary Seat Protection is  

installed.  The Secondary Seat Protection 

serves only as a backup to the primary 

seat for lockup.  Refer to the sections on 

Overpressure Protection and Maintenance.

M1131

ERAA03487

INLET PRESSURE

OUTLET PRESSURE

ATMOSPHERIC PRESSURE

RELIEF VALVE STEM

CONTROL SPRING

RELIEF VALVE 

SPRING

RELIEF SEAT

PRESSURE RETAINING 

PLUG (DO NOT REMOVE)

VALVE STEM

SECONDARY 

SEAT DETAIL

Summary of Contents for FISHER CS200 Series

Page 1: ...r Introduction Scope of the Manual This manual provides instructions for the installation maintenance and parts ordering information for Types CS200IN CS200IR CS205IN CS205IR and CS206IR service regulators Table of Contents Introduction 1 Specifications 3 Principle of Operation 4 Installation and Overpressure Protection 6 Startup 7 Adjustment 8 Shutdown 8 Maintenance 8 Parts Ordering 9 Parts List ...

Page 2: ...ly installed on industrial and commercial applications All constructions include internal pressure registration Types CS200IR CS205IR and CS206IR contain an internal relief valve Types CS200IN and CS205IN do not contain internal relief WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion and or fire causing property damage and...

Page 3: ...ssure registration and Relieving diaphragm assembly Type CS205IN Type CS200IN with Secondary SeatTM Protection Type CS205IR Type CS200IR with Secondary Seat Protection Type CS206IR Type CS200IR with Secondary Seat Protection with bleed to indicate that the Secondary Seat is providing lockup See also Table 1 Body Sizes End Connection Style and Pressure Rating 1 See Table 4 Outlet Pressure Ranges Se...

Page 4: ...scharge both with and without Secondary Seat Protection If emergency conditions should exist that prevent normal operation of the regulator or internal relief valve the relief valve stem acts as a secondary travel stop contacting the underside of the closing cap and stopping the upward travel of the relief seat When the diaphragm continues to rise as downstream pressure builds the diaphragm lifts ...

Page 5: ...into contact with a metal disk This metal to metal interface will allow a small amount of gas to bleed downstream thereby increasing outlet pressure until the Internal relief valve begins to discharge gas to the atmosphere The odor of this discharged gas provides an indication that the regulator is relying on the Secondary Seat for overpressure protection See Table 5 for the Downstream Pressure Bu...

Page 6: ...fering with proper operation Under enclosed conditions or indoors escaping gas may accumulate and be an explosion hazard In these cases the vent should be piped away from the regulator to the outdoors CAUTION The CS200 Series regulators have an outlet pressure rating lower than their inlet pressure rating If actual inlet pressure can exceed the outlet pressure rating outlet overpressure protection...

Page 7: ...rpressure Protection If the regulator is used in conjunction with a Type 289H relief valve it should be installed as shown in Figure 4 The outside end of the vent line should be protected with a rainproof assembly The Type 289H is typically set 10 inches w c 25 mbar higher than the outlet pressure setting of the regulator up to 30 inches w c 75 mbar outlet pressure For pressure greater than this s...

Page 8: ...tion before being returned to service Only parts manufactured by Regulator Technologies should be used for repairing Fisher regulators Restart gas utilization equipment according to normal startup procedures Due to normal wear or damage that may occur from external sources this regulator should be inspected and maintained periodically The frequency of inspection and replacement of parts depends up...

Page 9: ...19 is a friction fit O ring for Parts List Key Description Part Number Spare Parts Repair Parts Kit includes keys 21 36 55 and 62 Type CS200 RCS200X0012 1 Upper Case Aluminum GE24555X012 2 Vent Screen 18 8 Stainless steel T1121338982 3 Retaining Ring Zinc plated steel T1120925072 4 Stabilizer Guide Stainless steel GE27061X012 5 Stabilizer 1 inch 25 mm GE27063X012 6 Spring Stainless steel GE35010X0...

Page 10: ...7 1 TO 10 N m TORQUE 35 TO 45 FOOT POUNDS 47 TO 61 N m L1 60 L2 62 38 55 22 10 14 18 13 36 11 S S 21 L2 L2 L2 L1 L1 65 100 96 4 6 70 2 1 15 3 71 17 16 9 5 7 19 20 72 L1 25 L2 27 95 8 42 51 L1 TORQUE 15 TO 30 INCH POUNDS 1 7 TO 3 4 N m TORQUE 15 TO 30 INCH POUNDS 1 7 TO 3 4 N m TORQUE 15 TO 30 INCH POUNDS 1 7 TO 3 4 N m TORQUE 10 TO 13 FOOT POUNDS 14 TO 18 N m TORQUE 63 TO 90 INCH POUNDS 7 1 TO 10 ...

Page 11: ...s must be selected such that they meet the temperature requirements NON RELIEF STANDARD INTERNAL RELIEF Figure 6 CS200 Series Diaphragm Assemblies ERAA03487 ERAA03487 36 25 27 TORQUE 12 TO 17 FOOT POUNDS 16 T0 23 N m L1 L2 36 25 27 TORQUE 35 TO 45 FOOT POUNDS 47 T0 61 N m L1 L2 54 54 53 53 51 57 56 NOTE DIRECTION OF RETAINER RING INSTALLATION 55A 55A A 55B 45 43 43 44 58 42 41 51 57 A 55B ...

Page 12: ...fic Shanghai 201206 China Tel 86 21 2892 9499 The distinctive swirl pattern cast into every actuator casing uniquely identifies the regulator as part of the Fisher brand Commercial Service Regulator family and assures you of the highest quality engineering performance and support traditionally associated with Fisher Tartarini and Francel regulators Visit www fishercommercialservice com to access i...

Reviews: