background image

2

Press Connect

button

LOCATE AND MOUNT REMOTE SENSOR

IMPORTANT

Before drilling holes for mounting the Remote Sensor, verify the area(s) chosen for mounting allows good wireless 

communication to the Equipment Control Module. Place the remote(s) where they will be mounted (but do not drill holes 

yet) and follow steps in powering remote. If the remote sensors are out of range, status LED on sensor will flash red so 

a different location may be required.

POWERING THE REMOTE/CONNECTING TO 1F98EZ-1621

Indoor Remote Sensor

Locate Wireless Remote Sensor(s) 5’ off the ground in an area that 
represents the best location to average the temperature between 
Comfort Interface and Remote Sensor location.

Remove cover by holding Remote Sensor base and pressing the tab 
at the bottom toward the top. Continue to slide cover up to remove 
from base.

Use base to mark mounting hole location on wall. Drill mounting holes. 
Remote sensor can be attached to wall after checking operation.

For indoor use, the bracket is optional.

Cover

Base

Mounting 

Holes

Slide cover 

off of base

2 “AA” batteries

Outdoor Remote Sensor

If the sensor is going to be used outdoors, clip the indoor/outdoor 
jumper labelled W1.

Locate wireless remote sensor setup out of direct sunlight. Direct sun 
exposure will affect sensed temperature.

Make sure it is mounted in upright position and in a dry location 
under a covered area like a bay window or roof overhang.

NOTE

Mounting bracket must be used to mount outdoor sensor 

to provide a more moisture resistant seal. Be sure sensor 

is in up right position.

A mounting bracket is provided to keep the outdoor sensor away from 
the mounting surface and away from water buildup.

Install mounting bracket to wall at desired location. Outdoor Remote 
Sensor can be attached to mounting bracket after checking wireless 
operation.

Clip W1 for

outdoor use

Bracket

mounting

holes

Mounting

holes

Up

1.  Install batteries to power remote. LED will flash red and go off.

2.  Go to Equipment Control and press the Connect button. Equipment Control 

Status LED will blink green indicating searching for wireless devices.

3.  Press and hold the Connect button located on the inside of the Remote 

Sensor until LED starts flashing green then release button.  At the end of 

the flash sequence, observe three rapid  flashes  of the  LED to indicate the 

pairing has occured.

4.   The LED will switch to flash amber indicating the sensor number assigned.
 

1 amber flash = sensor 1

 

2 amber flashes = sensor 2

 

3 amber flashes 

= sensor 3

 

4 amber flashes = outdoor sensor 4

DH

M

2

DH

M

HM

2

HM

L

SYST

EM

POWE

R

RC

R

C

LED On/Off

Connect 

W/E

W2

Y

Y2

G

O/B

L

HM

HM2

DHM

SY

S

DRY

SY

S

DHM2

RC

RH

R

C

DRY

Equipment Control Module

Remote Sensor

DH

M

2

DH

M

HM

2

HM

L

SYST

EM

POWE

R

RC

R

C

LED On/Off

Connect 

W/E

W2

Y

Y2

G

O/B

L

HM

HM2

DHM

SY

S

DRY

SY

S

DHM2

RC

RH

R

C

DRY

Press Connect

button

Do not try to pair multiple RTS simultaneously. You can pair one RTS at a time and another after the previous one is 

completed pairing.

CAUTION

Summary of Contents for F145RF-1600

Page 1: ...nsor 2 Powering the Remote Connecting to 1F98EZ 1621 2 Confirm Wireless Devices are Communicating 3 How to Identify the Sensor Number 4 How to Check Battery Status 4 Remove Wireless Devices from the Wireless System 4 Troubleshooting 4 EquipmentControl Module Comfort Interface Remote Sensor outdoor location Model 1F98EZ 1641 Includes Comfort User Interface Equipment Control and oneWireless Remote S...

Page 2: ... in a dry location under a covered area like a bay window or roof overhang NOTE Mounting bracket must be used to mount outdoor sensor to provide a more moisture resistant seal Be sure sensor is in up right position A mounting bracket is provided to keep the outdoor sensor away from the mounting surface and away from water buildup Install mounting bracket to wall at desired location Outdoor Remote ...

Page 3: ... Remote Sensor 1 if installed Remote Sensor 2 if installed Outdoor Remote Sensor if installed Remote Sensor 3 if installed Return Air Sensor required 4 Press the Run button to return to Home screen 2 Press the Connect button once and release Comfort Interface display will indicate Searching until CTL control and wireless icon are found If no communication it will show Failed see Troubleshooting be...

Page 4: ...device to delete 5 Press the Run button to exit the menu 1 Press the Menu button once on the Comfort Interface and release 2 Press the Connect button once and release Comfort Interface display will indicate Searching until CTL control is found 3 Continue pressing and releasing the Next button to view the battery icon for all remote sensors RS 1 RS 2 RS 3 or ORS If battery needs to be replaced Chan...

Page 5: ...ICATIONS INDEX Page Détecteur à distance situer et monter 6 Alimentation du détecteur Branchement à 1F98EZ 1621 6 Confirmation que les périphériques sans fil communiquent entre eux 7 Identification du numéro de détecteur 8 Vérification du niveau des piles 8 Suppression de périphériques sans fil du système 8 Dépannage 8 Module de régulation d équipement Module de confort Détecteur à distance emplac...

Page 6: ...omme une fenêtre en baie ou un avant toit REMARQUE Le support de montage doit être utilisé pour installer le détecteur d extérieur afin d assurer une meilleure résistance à l humidité Vérifiez que le détecteur est à la verticale Le support de montage est fourni afin de garder le détecteur d extérieur à l écart de la surface de montage ainsi que de toute accumulation d eau Fixez le support de monta...

Page 7: ...ance d intérieur 2 si installé Détecteur à distance d extérieur si installé Détecteur à distance d intérieur 3 si installé Détecteur de retour d air requis 4 Enfoncez le bouton Run Exécuter pour retourner à l écran d accueil 2 Enfoncez le bouton Connect puis relâchez le L affichage du module de confort indiquera Searching Recherche jusqu à la détection CTL et l icône de connexion sans fil s affich...

Page 8: ...icheur indique l appareil suivant à supprimer 5 Enfoncez le bouton Run Exécuter pour quitter le menu 1 Enfoncez puis relâchez le bouton Menu sur le module de confort 2 Enfoncez puis relâchez le bouton Connect L affichage du module de confort indiquera Searching Recherche jusqu à la détection du module de régulation CTL 3 Continuez d enfoncer et de relâcher le bouton Next pour voir l icône de pile ...

Page 9: ...a Ubicación y montaje del sensor remoto 10 Alimentación del sensor remoto Conexión a 1F98EZ 1621 10 Confirmación de que los dispositivos inalámbricos se están comunicando 11 Cómo identificar el número de sensor 12 Cómo comprobar el estado de la pila 12 Desinstalación de los dispositivos inalámbricos del sistema inalámbrico 12 Solución de problemas 12 Módulo de control del equipo Interfaz de confor...

Page 10: ... de montarlo en posición vertical y en un lugar seco debajo de un área cubierta como una ventana o un alero NOTA El soporte de montaje debe utilizarse para montar el sensor externo para proporcionar un sellado más resistente a la humedad Asegúrese de que el sensor esté en posición vertical Se proporciona un soporte de montaje para mantener el sensor externo alejado de la superficie de montaje y le...

Page 11: ... 1 si está instalado Sensor remoto 2 si está instalado Sensor remoto externo si está instalado Sensor remoto 3 si está instalado Sensor de aire de retorno obligatorio 4 Presione el botón Run para volver a la pantalla Home 2 Presione el botón Connect una vez y suéltelo La interfaz de confort indicará Searching hasta encontrar el icono de control CTL y de inalámbrico Si no hay comunicación mostrará ...

Page 12: ...minar 5 Presione el botón Run para salir del menú 1 Presione el botón Menu una vez en la interfaz de confort y suéltelo 2 Presione el botón Connect una vez y suéltelo La interfaz de confort indicará Searching buscando hasta encontrar el control CTL 3 Continúe presionando y soltando el botón Next para ver el icono de la pila para todos los sensores remotos RS 1 RS 2 RS 3 u ORS Si es necesario cambi...

Reviews: