background image

For complete list of sales and manufacturing sites, please visit 

www.emerson.com/actuationtechnologieslocations

 

or contact us at 

[email protected]

World Area Confi guration Centers (WACC) offer sales support, service, 
inventory and commissioning to our global customers. 
Choose the WACC or sales offi ce nearest you:

NORTH & SOUTH AMERICA

19200 Northwest Freeway
Houston TX 77065
USA
T +1 281 477 4100

Av. Hollingsworth 
325 Iporanga Sorocaba 
SP 18087-105
Brazil
T +55 15 3413 8888

ASIA PACIFIC

No. 9 Gul Road
#01-02 Singapore 629361
T +65 6777 8211

No. 1 Lai Yuan Road
Wuqing Development Area
Tianjin 301700
P. R. China
T +86 22 8212 3300

MIDDLE EAST & AFRICA

P. O. Box 17033
Jebel Ali Free Zone
Dubai
T +971 4 811 8100

P. O. Box 10305
Jubail 31961
Saudi Arabia
T +966 3 340 8650

24 Angus Crescent
Longmeadow Business Estate East 
P.O. Box 6908 Greenstone 
1616 Modderfontein Extension 5
South Africa
T +27 11 451 3700

EUROPE

Holland Fasor 6
Székesfehérvár 8000
Hungary
T +36 22 53 09 50 

Strada Biffi 165
29017 Fiorenzuola d’Arda (PC)
Italy
T +39 0523 944 41

1

www.emerson.com/eim

©2018 Emerson. All rights reserved. 

The Emerson logo is a trademark and service mark of Emerson Electric Co. 
EIM

TM

 is a mark of one of the Emerson family of companies. 

All other marks are property of their respective owners.

The contents of this publication are presented for information purposes 
only, and while every effort has been made to ensure their accuracy, 
they are not to be construed as warranties or guarantees, express or 
implied, regarding the products or services described herein or their use 
or applicability. All sales are governed by our terms and conditions, which 
are available on request. We reserve the right to modify or improve the 
designs or specifications of our products at any time without notice.

Summary of Contents for EIM TEC2 500

Page 1: ...Quick Start Guide E2K 210 05 18 Rev 3 September 2018 EIM TEC2 Electric Actuator with Model 500 Quick Start Guide Model 500 Discontinued ...

Page 2: ......

Page 3: ...hics will display the mode of operation valve status position torque and alarm symbols The message center will display actuator setup options data entry feedback and alarm messages Once you follow the simple steps outlined in this guide the actuator will be ready for normal operation The bar graph position digits icons and LEDs will indicate the valve status LED Indicators Valve Torque Display Dia...

Page 4: ...controlled setting a unique network address If full data was not provided when ordering or if changes are needed see the TEC2 Installation Operation Manual E2K 420 0117 which can be found at www emerson eim Power Actuator Verify the voltage rating on the unit nameplate Connect power to the unit Are Position Limits Set Does SET LIMITS BEFORE OPERATING EE and the alarm icon appear and is the yellow ...

Page 5: ...Release quickly 1 STOP Place the selector knob in the STOP position Then toggle the control knob in rapid succession to YES then NO then YES then NO and release The Setup icon will be displayed on the display module and SETUP will be displayed on the message center Rotate the control knob to YES The message center will display SET LIMITS BEFORE OPERATING Set position limits as described on the nex...

Page 6: ...ed position is reached 1 STOP Turn the selector knob to the LOCAL position Hold the control knob in the CLOSE position until desired position is reached Dis engage motor drive by setting the declutch lever in HAND mode Using handwheel move the valve in the open direction for one handwheel turn to allow for motor coasting Re engage motor drive by setting the declutch lever out of HAND mode Return t...

Page 7: ...sition Hold the control knob in the OPEN position until desired position is reached Dis engage motor drive by setting the declutch lever in HAND mode Using handwheel move the valve in the close direction for one handwheel turn to allow for motor coasting Re engage motor drive by setting the declutch lever out of HAND mode Return the selector knob to the STOP position Select YES to set new open lim...

Page 8: ...osition At the CLOSE VALVE THEN SELECT STOP prompt depress the declutch lever while rotating the handwheel until the clutch is fully engaged Release the lever When the valve is fully closed Return the selector knob to the STOP position At the ACCEPT CLOSE LIMIT prompt select YES Advance to the SAVE CHANGES prompt and answer YES to save the changes 2 3 4 YES LOCAL 1 STOP 5 Depress declutch rotate h...

Page 9: ...L position At the OPEN VALVE THEN SELECT STOP prompt depress the declutch lever while rotating the handwheel until the clutch is fully engaged Release the lever When the valve is fully opened Return the selector knob to the STOP position At the SAVE LIMITS prompt select YES Advance to the SAVE CHANGES prompt and answer YES to save the changes 2 3 4 YES LOCAL 1 STOP 5 Depress declutch rotate handwh...

Page 10: ...en LED stays ON and 0 is displayed 1 When turning to close green LED blinks 2 When fully closed green LED remains lit Valve Open As you operate the valve in the open direction verify that the red LED is blinking When fully open is reached verify that the red LED stays ON and 100 is displayed 1 When turning to open red LED blinks 2 When fully open red LED remains lit Note It is also configurable to...

Page 11: ...r knob to the STOP position then toggle the control knob in rapid succession to YES then NO then YES then NO and release The setup icon will be displayed on the display module and SETUP will be displayed on the message center Rotate the control knob to YES The message center will display CHANGE DISPLAY SETTINGS 2 3 YES YES NO YES NO Release quickly 1 STOP ...

Page 12: ...etwork Controlled Changing the Valve Settings Answer NO to the Setup prompts until CHANGE SETTINGS appears Answer YES ACCEPT PASSCODE CHARACTER 1 X appears The factory default passcode is 000 Do not change the password without recording the new password 4 5 YES NO Until appears ...

Page 13: ...Valve Settings Enter Passcode Use the control knob and answer YES if the passcode character is correct If not use NO to advance incrementally to the correct character Repeat this process until three passcode characters are entered 6 7 YES NO If passcode character is correct to advance to correct character OR ...

Page 14: ...ings Quick Start Guide E2K 210 05 18 Rev 3 September 2018 12 Changing the Valve Settings Changing the Valve Settings Setting Limits Advance to the SET VALVE TRAVEL LIMITS prompt and answer YES Proceed to set limits 8 9 YES NO ...

Page 15: ...K SETUP using the selector knob in the REMOTE position Answer YES Hold the control knob in the NO position until the correct address appears Answer YES Unit is now network controlled If other configuration changes are needed please see the TEC2 Installation Operation Manual E2K 420 0117 which can be found at www emerson eim 2 3 4 YES NO Until 1 REMOTE 5 NO Until correct address YES ...

Page 16: ...Saving the Changes Quick Start Guide E2K 210 05 18 Rev 3 September 2018 14 Saving the Changes Saving the Changes Advance to the SAVE CHANGES prompt and answer YES to save the changes 1 2 YES NO CHANGES ...

Page 17: ......

Page 18: ...t Longmeadow Business Estate East P O Box 6908 Greenstone 1616 Modderfontein Extension 5 South Africa T 27 11 451 3700 EUROPE Holland Fasor 6 Székesfehérvár 8000 Hungary T 36 22 53 09 50 Strada Biffi 165 29017 Fiorenzuola d Arda PC Italy T 39 0523 944 411 www emerson com eim 2018 Emerson All rights reserved The Emerson logo is a trademark and service mark of Emerson Electric Co EIMTM is a mark of ...

Reviews: