background image

Page: 

  

Falkevej 12 

DK – 6705 Esbjerg Ø 

Tel.: +45 79 14 22 22

 

Pages incl. this one: 

Init.: 

CEH

 

Date: 

110207 

Approved: 

 

Drawing No.: 

8181101 

Version:

 

01 

Supplyer: 

 

Subject: 

Instr. XR30CX GB (medsendes fra termostat) 

 

Components must comply with the rules and restrictions stated in A/S Vestfrosts List of undesirable components/substances, and be 

free from silicone. 

 

This component must comply with the European Directive 2002/95/EC on the restriction of the use of certain hazardous substances in 

electrical and electronic equipment (RoHS directive). 

 

This drawing is the property of A/S Vestfrost and must not be copied, passed on to, or otherwise used by any person without the 

express consent of A/S Vestfrost.

Date: Last 

modification: 

Init: 

 

 

 

 
 
 
 

 

Denne vare er specificeret ved nedenstående datablad. Med forudgående skriftlig 

tilladelse fra Vestfrost, kan alternativ type/fabrikat anvendes. 

This product is specified according to the data sheet mentioned below. Alternative products/product types may only be used with the 

prior written consent of A/S Vestfrost. 

 
 
 
 
 
 

 
 
 
 

Se vedlagte 

Summary of Contents for Dixell XR30CX-4S1C1

Page 1: ...estriction of the use of certain hazardous substances in electrical and electronic equipment RoHS directive This drawing is the property of A S Vestfrost and must not be copied passed on to or otherwise used by any person without the express consent of A S Vestfrost Date Last modification Init Denne vare er specificeret ved nedenstående datablad Med forudgående skriftlig tilladelse fra Vestfrost k...

Page 2: ...the digital input can operate as third temperature probe The battery backup version is also provided with an input for external battery It is used to supply the controller in case of main voltage failure By using the HOT KEY input output port is possible to upload a new parameter map from program the controller or save the actual parameter map to an external memory device named HOTKEY memory Moreo...

Page 3: ...0 1 25 5 C 1 255 F intervention differential for set point Compressor Cut IN is Set Point differential HY Compressor Cut OUT is when the temperature reaches the set point LS Minimum set point 100 C SET 148 F SET it sets the minimum value for the set point US Maximum set point SET 150 C SET 302 F it sets the maximum value for set point ot Thermostat probe calibration 12 0 12 0 C 120 120 F allows to...

Page 4: ...ing function allows to change the set point value as the result of the SET HES parameter sum This function is enabled until the digital input is activated 8 8 DIGITAL INPUTS POLARITY The digital input polarity depends on the i1P parameter i1P CL the input is activated by closing the contact i1P OP the input is activated by opening the contact 9 TTL SERIAL LINE FOR MONITORING SYSTEMS It is possible...

Page 5: ... 60 Pr2 CoF Compressor OFF time with faulty probe 0 255 min 5 5 Pr2 CH Kind of action CL cooling Ht heating CL CL Pr2 CF Temperature measurement unit C F C C Pr2 rES Resolution in integer dE dec point in in Pr2 dLY Display temperature delay 0 20min 00s res 10s 0 0 0 0 Pr2 idF Interval between defrost cycles 1 120 hours 0 0 Pr1 MdF Maximum length for defrost 0 255 min 0 0 Pr1 dFd Displaying during ...