background image

 

 

 
 
 
 

 

 

 

 

 

Controllers for electric 

ovens  

XF330M – XF331M – 

XF332M

 

 

 

  

Summary of Contents for Dixell XF330M

Page 1: ...Controllers for electric ovens XF330M XF331M XF332M ...

Page 2: ... the right to change the composition of its products even without notice ensuring the same and unchanged functionality 1 2 Safety Precautions Check the supply voltage is correct before connecting the instrument Do not expose to water or moisture use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensatio...

Page 3: ...rt of the oven DAILY REPETITION to set the current day and to select the days for the automatic start of the oven PRG to set and select the pre programmed cooking cycles EXTRACTOR Switch on and off the steam extractor Not present in the XF331M STEAM ENABLING Switch on and off the steam generator relay Not present in the XF332M STEAM INJECTION Enables the steam injection ENERGY SAVING enables the e...

Page 4: ...the SET key or wait 10s to exit and confirm the setting NOTE To change quickly the temperatures hold pressed the UP and DOWN keys 5 2 How to set and modify the cooking time 1 Push the TIMER key 2 The TIME display will show the cooking time hour and minutes The LED of the key will be turned on 3 To change the value push UP and DOWN buttons on the right of the display 4 To memorise the new time push...

Page 5: ...en is on push and release the DAILY REPETITION key 2 The TIME display shows the dAy1 Monday message If the led of the DAILY REPETITION key is on it means that the automating starting is enabled for Monday 3 To enabled or disable the automatic starting push and release the DAILY REPETITION key The led is turned on and off respectively 4 Use the UP key to see the other day of the week day2 Thursday ...

Page 6: ...program After selecting a programme the PRG LED is on push the START key to start the cooking cycle 8 Steam 8 1 Steam generator Not present in XF332M By pushing the STEAM key the relay of the steam generator is switched The status of the Generator is monitored by the led if the led is ON the generator is working if the LED is off the generator is off XF331M the XF331M is provided with a digital in...

Page 7: ... of the extractor is monitored by the led if the led is ON the extractor is working if the LED is off the extractor is off 9 2 Automatic activation of the steam extractor before the end of a cooking cycle The extractor can be activated automatically some minutes before the end of a cooking cycle To set the time act as follow 1 Push the EXTRACTOR key till the time display will show the activation t...

Page 8: ...inimum set point limit for ceiling Down scale set1 Sets the minimum acceptable value for the set point of ceiling US1 Maximum set point limit for ceiling SET1 End scale Set the maximum acceptable value for set point of ceiling Hy2 Bottom differential 99 99 C Intervention differential for the bottom set point Output is activated when the bottom temperature is less than Set Point Hy2 LS2 Minimum set...

Page 9: ...ching on percentage for the ceiling output during the Energy Saving cycle 0 100 i1P Digital input polarity to enabling steam injection only for XF331M oP CL oP the steam injection is enabled if voltage is not present CL the steam injection is enabled if voltage is present Ptb Parameter table code read only it shows the original code of the map rEL Release software read only Software version of the...

Page 10: ...ature alarms HA and LA automatically stop as soon as the temperature returns to normal values 17 3 Probe failure alarms PF Probe alarm PF starts some seconds after the fault in the related probe it automatically stop some seconds after the probe restarts normal operation Check connections before replacing the probe 17 4 Real time clock alarm rtc The rtc alarm is signalled when an error happened du...

Page 11: ... 8A 250Vac 12A 250Vac 8A 250Vac 8A 250Vac 8A 250Vac C 8A 250Vac 22 230Vac input for injection enabling L N 6 2 1 12 9 3 13 8 5 10 11 14 17 18 16 Light C C C Fan XF332M 8A 250Vac 12A 250Vac 8A 250Vac 8A 250Vac 8A 250Vac C 8A 250Vac 20 Cooking programs pre set values Ceiling set Bottom set Time Program 1 100 100 30 min Program 2 100 100 30 min Program 3 100 100 30 min Program 4 100 100 30 min Progra...

Page 12: ...10 Pr1 10 Pr1 Tco Steam injection time 0 60 min 3 Pr1 3 Pr1 3 Pr1 HSi Maximum time for steam injection 0 60 sec 10 Pr1 10 Pr1 10 Pr1 TES Automatic activation of the steam extractor before the end of cooking 0 99 min 0 Pr1 0 Pr1 tFS Fan restarting delay after steam injection 0 99 min 0 Pr1 Ac1 Ceiling temperature alarm configuration Ab absolute rE relative Ab Pr2 Ab Pr2 Ab Pr2 AL1 Low temperature a...

Reviews: