Condensing Unit For Refrigeration Networks
3.7.4 3 Unit Network : Installation, dimensions and piping details
Medium Temperature Network
Low Temperature Network
10
00 m
m
22
40 m
m
+/- 600 mm
+/- 4900 mm
Oil distribution circuit
Ai
r F
lo
w
Ai
r F
lo
w
Ai
r F
lo
w
Communication cable
Suction pipe from evaporator(s)
Liquid pipe to evaporator(s)
10
00 m
m
22
40
m
m
+/- 600 mm
+/- 4900 mm
Oil distribution circuit
Ai
r F
lo
w
Ai
r F
lo
w
Ai
r F
lo
w
Communication cable
Suction pipe from evaporator(s)
Liquid pipe to evaporator(s)
Low temperature networks need additional piping between each unit heat exchanger and
the receiver, in order to get liquid for vapour injection.
IMPORTANT
For low temperature network systems, Copeland recommends to insulate the complete
liquid outlet line to the expansion valve in order to optimise the sub-cooling effect.
C6.1.4/0305/E
25