background image

SWITCH HOUSING/ 
LIGHT KIT FITTER 
ASSEMBLY

60-WATT 
CANDELABRA 
BASE LIGHT 
BULB (3)

FINIAL NUT

OUTER 
BOWL CAP

Figure 10

7

emersonfans.com

Please contact 1-800-654-3545 for further assistance

E.T.L. Model No.: CF776

THREADED NIPPLE

LIGHT FITTER

GLASS
BOWL

60-WATT
CANDELABRA
BASE BULBS (3)

FINIAL NUT

OUTER BOWL
CAP

LIGHT SWITCH
CHAIN

PENDANTS (2)

CHAIN GUIDE

FAN SWITCH
CHAIN

Figure 11

20.

Install three 60-watt (maximum) candelabra base
light bulbs (included) into the light fitter sockets
(Figure 10).

21.

Remove the finial nut and outer bowl cap from the
light fitter (Figure 11).

22.

Pass the fan switch chain through the bushing in
the bowl cap (Figure 11).

23.

Position the glass bowl over the threaded nipple.
Slide the outer bowl cap onto the threaded
nipple and gently tighten the finial nut to secure the
glass bowl.  Pass the fan pull chain through the
bushing in the outer bowl cap and install the cap on
the threaded nipple. Install finial nut finger tight
(Figure 11).

CAUTION

Be sure that the fan switch chain does not make
contact with the light bulbs. If necessary
reposition the light fitter to avoid the fan switch
chain from touching the light bulbs.

24.

Install pendants onto light fixture chain and fan
switch chain using couplers provided.

NOTE: It is advisable to periodically check the
tightness of the finial.

25.

You have now completed the assembly of your new
ceiling fan. You can now proceed with hanging and
wiring your fan.

Over lamping the fan will result in the light bulbs being
automatically shut off. Use only 60-watt maximum
candelabra light bulbs. Turn off the electricity before
replacing the light bulbs.

WARNING

!

To avoid possible fire hazard, do not exceed wattage
indicated on the fitter.

WARNING

!

Summary of Contents for CF776BS00

Page 1: ...EY LUMINA 52 Ceiling Fan Owner s Manual Model Numbers CF776BS00 Brushed Steel CF776ORB00 Oil Rubbed Bronze CF776SW00 Satin White Net Weight 28 9 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com ...

Page 2: ...n blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock...

Page 3: ...ailer or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly A B C D E F J H K G I PACKAGE CONTENTS 1 4 3 7 12 2 6 5 8 11 10 9 Part Description Quantity A Fan Motor Assembly 1 ...

Page 4: ...anger ball for reinstallation in Step 5 2 Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Align the clevis pin holes in the downrod with the holes in the motor coupler Install the clevis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor coupler and the holes in the downrod Be sure to push the stra...

Page 5: ... blue black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 7 Mount blade flange to fan blade using three 10 32 x 25 slotted Phillips washers head screws Figure 5 8 Repeat this procedure for the remaining four blades and flange...

Page 6: ...ly to the black wire of the light fitter Figure 8 17 Engage the connector of the switch housing assembly with the motor connector Figure 9 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the connector latch closes properly 18 Carefully tuck all wires and splices into the switch housing 19 Position the switch housing assem...

Page 7: ...tly tighten the finial nut to secure the glass bowl Pass the fan pull chain through the bushing in the outer bowl cap and install the cap on the threaded nipple Install finial nut finger tight Figure 11 CAUTION Be sure that the fan switch chain does not make contact with the light bulbs If necessary reposition the light fitter to avoid the fan switch chain from touching the light bulbs 24 Install ...

Page 8: ...installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal airflow Consult your Emerson Retailer for ...

Page 9: ...he risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 15 9kg 35 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance ...

Page 10: ...ads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 16 Check to see that all connections are...

Page 11: ...Fan Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING SPEED CONTROL PULL CHAIN SWITCH REVERSING SWITCH LIGHT PULL CHAIN SWITCH IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint fre...

Page 12: ...12 E T L Model No CF776 Repair Parts 1 5 2 3 4 6 16 7 17 9 8 12 21 11 22 19 18 15 20 13 14 10 23 24 25 10 ...

Page 13: ...ag Containing 764388 CHRM 764388 BLOX 764388 CHRM 4 Wire Connector 3 5 Threaded Stud 2 6 Lockwasher 2 7 Knurled Knob 2 8 Pin Clevis 9 Clip Hairpin 10 Wood Ball Chain 11 Screw 1 4 20 x 5 11 12 Screw 10 32 x 25 16 13 Screw Switch Cup 4 14 Screw Switch Adapter 1 15 Blade Balance Kit 16 Ceiling Canopy 764389 BS 764389 ORB 764389 SW 17 Coupler Cover 764390 BS 764390 ORB 764390 SW 18 Wiring Harness 7643...

Page 14: ... to signals from Solid State speed control variable speed controls If Solid State Control is used and motor noise results choose an alternative control method 5 Screws holding blades to flanges are loose 5 Tighten screws securely 3 Fan wobbles 1 Setscrews in motor coupler are not 1 Raise coupler cover and tighten setscrews securely excessively tightened securely 2 Setscrew in the hangerball downro...

Page 15: ...is limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returni...

Page 16: ...r Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74680000 Form No BP7468 Revision 130228 E T L Model No CF776 Printed in China 02 13 ...

Reviews: