background image

2

Safety Instructions

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK,
OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
a. Use this unit only in a manner intended by the

manufacturer.  If you have questions, contact the
manufacturer.

b. Before servicing or cleaning unit, switch power off

at service panel and lock service panel
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a warning device, such as a tag, to the
service panel.

WARNING

!

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned

off at the fuse box before wiring, and do not operate
fan without blades.

2. All wiring must be in accordance with the National

Electrical Code “ANSI/NFPA 70-2011” and Local
Electrical Codes. Use the National Electrical Code if
Local Codes do not exist. The ceiling fan must be
grounded as a precaution against possible electrical
shock. Electrical installation should be made or
approved by a licensed electrician.

3. The outlet box and joist must be securely mounted

and capable of reliably supporting at least 50 pounds.
Use only U.L. outlet boxes listed as “Acceptable for
Fan Support of 15.9kg. (35 lbs.) or less”, and use the
mounting screws provided with the outlet box. Most
outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may
need to be replaced. Consult a qualified electrician if
in doubt.

4. The downrod furnished with the fan provides the

minimum recommended floor to fan blade clearance
for an 8 foot ceiling.

5. The fan must be mounted with the fan blades at least

7 feet from the floor to prevent accidental contact with
the fan blades.

6. Follow the recommended instructions for the proper

method of wiring your ceiling fan. If you do not know
enough about electrical wiring, have your fan installed
by a licensed electrician.

WARNING: 

To reduce the risk of electrical shock, this

fan must be installed with an isolating wall
control/switch.

NOTE:

This fan is suitable for use with solid-state speed

controls.

WARNING:

This product is designed to use only those

parts supplied with this product and/or any accessories
designated specifically for use this product by Emerson
Electric Co. Substitution of parts or accessories not
designated for use with this product by Emerson could
result in personal injury or property damage.

WARNING: 

To reduce the risk of personal injury, do not

bend the blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not insert
foreign objects in between rotating fan blades.

NOTE:

All setscrews must be checked and re-tightened

where necessary before installation.

1. Read your owner’s manual carefully and keep it for

future reference.

2. Be careful of the fan and blades when cleaning,

painting, or working near the fan. Always turn off the
power to the ceiling fan before servicing.

3. Do not put anything into the fan blades while they are

turning.

4. Do not operate reversing switch until fan blades have

come to a complete stop.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label. You should record

this data above and keep it in a safe place for future use.

E.T.L. Model No.: CF776

READ AND SAVE THESE INSTRUCTIONS

Summary of Contents for CF776BS00

Page 1: ...EY LUMINA 52 Ceiling Fan Owner s Manual Model Numbers CF776BS00 Brushed Steel CF776ORB00 Oil Rubbed Bronze CF776SW00 Satin White Net Weight 28 9 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com ...

Page 2: ...n blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock...

Page 3: ...ailer or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly A B C D E F J H K G I PACKAGE CONTENTS 1 4 3 7 12 2 6 5 8 11 10 9 Part Description Quantity A Fan Motor Assembly 1 ...

Page 4: ...anger ball for reinstallation in Step 5 2 Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Align the clevis pin holes in the downrod with the holes in the motor coupler Install the clevis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor coupler and the holes in the downrod Be sure to push the stra...

Page 5: ... blue black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 7 Mount blade flange to fan blade using three 10 32 x 25 slotted Phillips washers head screws Figure 5 8 Repeat this procedure for the remaining four blades and flange...

Page 6: ...ly to the black wire of the light fitter Figure 8 17 Engage the connector of the switch housing assembly with the motor connector Figure 9 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the connector latch closes properly 18 Carefully tuck all wires and splices into the switch housing 19 Position the switch housing assem...

Page 7: ...tly tighten the finial nut to secure the glass bowl Pass the fan pull chain through the bushing in the outer bowl cap and install the cap on the threaded nipple Install finial nut finger tight Figure 11 CAUTION Be sure that the fan switch chain does not make contact with the light bulbs If necessary reposition the light fitter to avoid the fan switch chain from touching the light bulbs 24 Install ...

Page 8: ...installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal airflow Consult your Emerson Retailer for ...

Page 9: ...he risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 15 9kg 35 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance ...

Page 10: ...ads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 16 Check to see that all connections are...

Page 11: ...Fan Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING SPEED CONTROL PULL CHAIN SWITCH REVERSING SWITCH LIGHT PULL CHAIN SWITCH IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint fre...

Page 12: ...12 E T L Model No CF776 Repair Parts 1 5 2 3 4 6 16 7 17 9 8 12 21 11 22 19 18 15 20 13 14 10 23 24 25 10 ...

Page 13: ...ag Containing 764388 CHRM 764388 BLOX 764388 CHRM 4 Wire Connector 3 5 Threaded Stud 2 6 Lockwasher 2 7 Knurled Knob 2 8 Pin Clevis 9 Clip Hairpin 10 Wood Ball Chain 11 Screw 1 4 20 x 5 11 12 Screw 10 32 x 25 16 13 Screw Switch Cup 4 14 Screw Switch Adapter 1 15 Blade Balance Kit 16 Ceiling Canopy 764389 BS 764389 ORB 764389 SW 17 Coupler Cover 764390 BS 764390 ORB 764390 SW 18 Wiring Harness 7643...

Page 14: ... to signals from Solid State speed control variable speed controls If Solid State Control is used and motor noise results choose an alternative control method 5 Screws holding blades to flanges are loose 5 Tighten screws securely 3 Fan wobbles 1 Setscrews in motor coupler are not 1 Raise coupler cover and tighten setscrews securely excessively tightened securely 2 Setscrew in the hangerball downro...

Page 15: ...is limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returni...

Page 16: ...r Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74680000 Form No BP7468 Revision 130228 E T L Model No CF776 Printed in China 02 13 ...

Reviews: