27
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF135
10. Transmitter Battery Installation and Code Setting
(Continued)
BATTERY COVER
B
a
tt
e
ry
REMOTE CONTROL
TRANSMITTER
BATTERY
BATTERY
CONNECTOR
Figure 50
10.2
PRESET MEMORY FEATURE
Your Emerson receiver is equipped with a preset memory
feature. If the AC supply to the receiver is powered
through a wall switch, when the switch is turned OFF, the
control will remember the light intensity and fan speed.
When the switch is turned back ON the light and fan will
resume operation as they were prior to the switch being
turned OFF.
10.3
Remove the battery cover by pressing firmly below the
arrow and sliding the cover off the control (Figure 50).
Remove the connector from the battery compartment and
install 9-volt alkaline battery.
BATTERY COVER
CODE SWITCH
B
a
tt
e
ry
REMOTE
CONTROL
TRANSMITTER
TRANSMITTER CODE
SWITCHES 1, 2, 3, AND 4
ON
1
2
3
4
X
D
DIMMING
ON
DIMMING
OFF
ON
Figure 51
10.4
SETTING THE OPERATING
FREQUENCY OF THE HANDHELD
REMOTE CONTROL TRANSMITTER
Your remote control transmitter has code switches which
must be set in one of 16 possible code combinations.
The four levers (numbered 1, 2, 3, and 4) on the switches
are factory-set in the ON (up) position (Figure 51).
Do not use this setting. Change the switch settings as
follows:
Slide the four switch levers in the remote control
(transmitter) to your choice of ON (up) or down positions.
Use a ball-point pen or small screwdriver and slide the
levers firmly up or down.
The fifth switch labeled “X” controls the light dimming of
the remote control. Setting the switch to the "D" position
allows the controls to dim the light kit from a low setting up
to full intensity. Disable the dimming feature by setting the
code switch to the "X" position.
NOTE: Non-dimming fluorescent lamps will flicker
when using the dimming feature. Your fan is
supplied with non-dimming fluorescent lamps. Set the
dimming switch to the "X" position to turn the
dimming feature off.