Page 16
Product Information / Produktinformation
A6312
Rotational Speed Monitor
Function outputs
Opto
−
decoupled collector / emitter lines
Out 1
−
1 C / Out 1
−
1 E
d26 (collektor) / d28 (emitter)
Out 1
−
2 C / Out 1
−
2 E
b26 (collektor) / b28 (emitter)
Out 2
−
1 C / Out 2
−
1 E
d30 (collektor) / d32 (emitter)
Out 2
−
2 C / Out 2
−
2 E
b30 (collektor) / b32 (emitter)
Maximum values for alarm outputs
C
−
E off:
max. voltage U
CE
= 48 V
C
−
E conducting: max. current I
CE
= 100 mA
active state of function outputs
conducting in the open circuit mode
switched of in the closed circuit mode
Open circuit / closed circuit mode
Selectable by means of external signal inversion at binary inputs d24 and z24, only for the
function outputs Out 1
−
1 and Out 2
−
1.
Outputs Out 1
−
2 and Out 2
−
2 are invariably fixed to open circuit mode
Switch over Out 1
−
1
d24 = HIGH / open
→
open circuit mode
d24 = LOW
→
closed circuit mode
Switch over Out 2
−
1
z24 = HIGH / open
→
open circuit mode
z24 = LOW
→
closed circuit mode
Switching level
LOW: 0 ... +3 V
HIGH: 13 ... 48 V
Input resistance
>10 k
Ω
1.6.4 Communication interfaces
RS 232 interface
Front socket for connecting a laptop / computer for configuration and visualization purposes
Round plug connector
on the front side
Mini DIN socket type TM 0508A/6 for
parameterization cable (included in the operating kit)
RS 485 interface
d4, z4 bus interface for communication with an MMS 68xx epro analysis and diagnostic
system and the configuration software.