ATCA-F140 Installation and Use (6806800M67H)
Safety Notes
124
Damage to blade/Backplane or System Components
Bent pins or loose components can cause damage to the blade, the backplane, or other system
components. Therefore, carefully inspect the blade and the backplane for both pin and
component integrity before installation.
Data
loss
Removing the blade with the blue LED still blinking causes data loss. Wait until the blue LED is
permanently illuminated before removing the blade.
System
Damage
The intra-building port(s) of the equipment or subassembly is suitable for connection to
intrabuilding or unexposed wiring or cabling only. The intra-building port(s) of the equipment
or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or
its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 or
Type 4 ports as described in GR-1089) and require isolation from the exposed OSP cabling. The
addition of Primary Protectors is not sufficient protection in order to connect these interfaces
metallically to OSP wiring.
Operation
Blade
Damage
High humidity and condensation on the blade surface causes short circuits. Do not operate the
blade outside the specified environmental limits. Make sure the blade is completely dry and
there is no moisture on any surface before applying power. Do not operate the blade below -
5°C.
Overheating and Blade Damage
Operating the blade without forced air cooling may lead to overheating and thus damage of
the blade. When operating the blade, make sure that forced air cooling is available in the shelf.