3.3 Key to parameter codes
In the following sections descriptions are given for the advanced parameter set. With each parameter the following information block is given.
The top row gives the menu:parameter number and the parameter name. The other rows give the following information.
3.3.1 Coding
The coding defines the attributes of the parameter as follows.
3.3.2 Term
definitions
Range
This gives the range of the parameter and the values it can be adjusted to.
Default
The default values given are the standard drive defaults.
Second motor parameter
Some parameters have an equivalent second motor map value that can be used as an alternative when a second motor is selected with Pr
11.45
.
Menu 21 contains all the second motor map parameters.
Update rate
Defines the rate at which the parameter data is written by the drive or read and acted upon by the drive. Where background update rate is specified,
the update time depends on the drive processor load. Generally the update time is between 10ms and 100ms, however, the update time is
significantly extended when loading defaults, transferring data to/from a SmartStick, or transferring blocks of parameters to/from the drive via the drive
serial communications port.
5.11
Number of motor poles
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
1
Range
Auto(0), 2P(1), 4P(2), 6P(3), 8P(4)
Default
Auto(0)
Second motor
parameter
Pr
Update rate
Background
Coding
Attribute
Bit
1 bit parameter
SP
Spare: not used
FI
Filtered: some parameters which can have rapidly changing values are filtered when displayed on the drive keypad for easy
viewing.
DE
Destination: indicates that this parameter can be a destination parameter.
Txt
Text: the parameter uses text strings instead of numbers.
VM
Variable maximum: the maximum of this parameter can vary.
DP
Decimal place: indicates the number of decimal places used by this parameter.
ND
No default: when defaults are loaded (except when the drive is manufactured or on EEPROM failure) this parameter is not
modified.
RA
Rating dependant: this parameter is likely to have different values and ranges with drives of different voltage and current ratings.
These parameters are not transferred by the SmartStick when the rating of the destination drive is different from the source drive.
NC
Not copied: not transferred to or from the SmartStick during parameter copying.
NV
Not visible: not visible on the keypad.
PT
Protected: cannot be used as a destination.
US
User save: saved in drive EEPROM when the user initiates a parameter save.
RW
Read/write: can be written by the user.
BU
Bit default one/unsigned: Bit parameters with this flag set to one have a default of one (all other bit parameters have a default of
zero. Non-bit parameters are unipolar if this flag is one.
PS
Power-down save: automatically saved in drive EEPROM at power-down.