  OPERATING YOUR THERMOSTAT

To prevent compressor and/or property damage, if the 
outdoor temperature is below 50°F, DO NOT operate 
the cooling system.

CAUTION

!

Cooling

1.  Press SYSTEM to select 

"Cool"

.

2. Press   to adjust the thermostat setting below room 

temperature. The blower should come on immediately on 
high speed, followed by cold air circulation. The display 
should show "

System On"

. If the setpoint temperature 

display is flashing, the compressor lockout feature is 
operating (see Configuration menu, item 11).

3. Press   to adjust the temperature setting above room 

temperature. The cooling system should stop operating.

Choose the Fan Setting (Auto or On or Prog)

There are two fan features  on the 1F95-1277

1. 

Fan Auto/On 

- T

raditional Fan Settings 

 

Press 

Fan

 to select 

Auto 

or 

On

. The most commonly 

used setting is 

Auto. Fan Auto

 runs the fan only when the 

heating or cooling system is operating. Selecting 

Fan

 

On

 

runs the fan continously for increased air circulation or to 
allow additional air cleaning if the system is equipped with 
an Electronic Air Cleaner.

2. 

FAN Prog

 

- Comfort Circulating fan Feature

 

 Pressing 

Fan

 until 

FAN Prog

 appears activates the 

Comfort Circulating Fan Option. This causes the 
thermostats to cycle the fan on for 10 minutes and off for 

room temperature. The heat pump system should 
begin to operate. The display should show "

System 

On"

. However, if the system configuration is set to 

HP1 and setpoint temperature display is flashing, the 
5 minute compressor lockout feature is operating (see 
Configuration menu, item 11).

3.  Adjust temperature setting to 3° above room temperature. 

If your system configuration is set at HP1 the auxiliary 
heat system should begin to operate and the display will 
show 

"System On +2"

.

4. Press   to adjust the thermostat below room 

temperature. The heating system should stop operating.

Emergency Mode

Applies only to Heat Pump Systems

Emergency Heat (System EM Position) 

bypasses the Heat 

Pump to use the heat source wired to terminal 

W/E 

on the 

thermostat. 

EM

 is typically used when compressor operation 

is not desired, or you prefer back-up heat only.
1.  Press SYSTEM key to select 

EM

“EM Heat Mode” 

will 

flash on the display.

2. Press   to adjust thermostat setting above room 

temperature. The Emergency heating system will begin 
to operate. The display will show 

“System On + 2”

 

flashing 

“EM Heat Mode” 

and “Heat” to indicate that the 

Emergency system is operating.

3. Press   to adjust the thermostat below room 

temperature. The heating system should stop operating.

20 minutes if the thermostat has not called for heat or 
cool during the past 60 minutes. This assures moderate 
air ci rculation even when the heating and cooling 
equipment is not cycling.

Choose the System Setting

(Cool, Off, Heat, Em, Auto)

Press the SYSTEM key to select:

Cool: 

Thermostat controls only the cooling system.

Off: 

Heating and Cooling systems are off. 

Heat: 

Thermostat controls only the heating system.

Em: 

Setting is available only when the thermostat is 

configured in HP1 mode.

Auto: 

Auto Changeover is used in areas where both heating 

and cooling may be required on the same day. 

AUTO

 allows 

the thermostat to automatically select heating or cooling 
depending on the indoor temperature and the selected heat 
and cool temperatures. When using 

AUTO

, be sure to set the 

Cooling temperatures more than 1° Fahrenheit higher than 
the heating temperature.

Manual Operation for

Non-Programmable Mode

Press the SYSTEM key to select 

"Heat"

 or 

"Cool"

 and use

the keys to adjust the temperature to your desired setting. 
After selecting your desired settings you can also press 
the SYSTEM key to select 

AUTO

 to allow the thermostat to 

automatically change between 

"Heat"

 and 

"Cool"

.

Manual Operation (Bypassing the Program)

Programmable Mode

Manual operation will bypass the program and allow you 
to adjust the temperature as you desire. The temperature 
you set in 

Hold

 will be maintained indefinitely. Press 

 or 

 to adjust the temperature. The HOLD key will appear. 

Press the HOLD key. "

Hold At"

 will appear next to the 

setpoint temperature and the thermostat will maintain the 
new setpoint temperature until 

Run Schedule

 is pressed to 

resume program operation.

Program Override (Temporary Override)

Press 

 or 

 keys to adjust the temperature. This will 

override the temperature setting for a (default) four hour 
override period. The override period can be shortened by 
pressing   or lengthened by pressing  . Program Override 
period can range from 15 minutes to 7 days.

Example: 

If you turn up the heat during the morning 

program, it will be automatically lowered later, when the 
temporary hold period ends. To cancel the temporary setting 
at any time and return to the program, press 

Run Schedule

.

If the SYSTEM key is pressed to select 

AUTO

 the

thermostat will change to 

"Heat"

 or 

"Cool"

, whichever 

ran last. If it switches to 

"Heat"

, but you want 

"Cool"

, or it 

changes to 

"Cool"

, but you want 

"Heat"

, press both keys 

simultaneously to change to the other mode.

Summary of Contents for 1F97-1277

Page 1: ...products containing mercury must not be discarded in household trash Do not touch any spilled mercury Wearing non absorbent gloves clean up any spilled mercury and place in a sealed container For proper disposal of a product containing mercury or a sealed container of spilled mercury place it in a suitable shipping container Refer to www thermostat recycle org for location to send the product cont...

Page 2: ...hes The Power Stealing Switches Fig 1 should be left in the On position for most systems The information in the following table details the thermostat power method and switch options WARNING Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code INSTALLATION Figure 1 Thermostat Base Multi Stage 1F97 1277 2 AA Batteries Power Stealing Sw...

Page 3: ...tem You can configure the thermostat for use with the following fossil fuel systems Heat Pump 1 HP1 System RC RH C Y W E G O B 6 L CLASS II TRANSFORMER HOT 24VAC NEUTRAL 120VAC Heat mode 2nd stage Emergency Mode 1st stage Note Dual Fuel option de energizes Heat mode stage 1 compressor when auxiliary heat is energized 24 volt power for cooling 24 volt power for heating 24 volt common optional for s...

Page 4: ...Items 7 15 6 5 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 19 20 2 1 11 10 15 16 9 8 17 13 12 4 18 15 Remote indicates that the indoor remote temperature sensor is being accessed Outdoor Remote indi cates the outdoor remote temperature sensor is being accessed 16 Display time remote temperature 17 Heat ...

Page 5: ...ycle rate Heat 9 FA Cool Cr SL Selects Adjustable Anticipation cycle rate Cool 10 FA Cr AU Em SL Selects Adjustable Anticipation cycle rate auxiliary This item is only to appear if HP1 or HP2 is selected above 11 OFF SC On Select stage cycle completion On or Off 12 OFF CL On Selects Compressor Lockout 13 OFF dL On Selects Continuous Display backlight 14 0 Temperature 5 LO to 5 HI Selects Adjustabl...

Page 6: ...plete heating and or cooling cycles on the highest stage engaged during the cycle Thermostat will not reduce heating or cooling stages be fore the heating or cooling cycle is satisfied and all stages are turned off 12 Select Compressor Lockout CL Selecting CL On will cause the thermostat to wait 5 minutes between cool ing cycles This is intended to help protect the compressor from short cycling So...

Page 7: ...en using this feature The temperature limit icon will flash if an attempt is made to adjust the temperature beyond the range selected 25 Cool Temperature Limit Range This feature adjusts the lowest setpoint temperature for cool The default setting is 45 F It can be changed to a setting between 46 F and 82 F The temperature limit icon will be dis played to the left of your setpoint temperature when...

Page 8: ... is delayed for the time selected in seconds This delay is factory set to 60 but can be set in the range of 0 to 99 35 Select Auxiliary Off AO Applicable with HP1 or HP2 selected with outdoor sensor Select the temperature that will inhibit the auxiliary heating stage As long as the outdoor temperature is above the selected temperature the auxiliary heat will not turn on The default setting is 80 d...

Page 9: ... that the Emergency system is operating 3 Press to adjust the thermostat below room temperature The heating system should stop operating 20 minutes if the thermostat has not called for heat or cool during the past 60 minutes This assures moderate air ci rculation even when the heating and cooling equipment is not cycling Choose the System Setting Cool Off Heat Em Auto Press the SYSTEM key to selec...

Page 10: ...step or press Advance Day until the day you wish to copy to is flashing 5 Press Copy Copy will disappear the day you copied from will disappear and the day s you copied to will be on 6 If you wish to copy this same program into other days press Copy and repeat steps 3 4 and 5 7 Press Run Schedule to return to normal operation Fill in the blank schedule on the next page then Enter the Heating Progr...

Page 11: ... You can eliminate these two program periods in the configuration menu reference 5 if the building is occupied all day Day period will change to 6 00 AM and 70 and can be programmed as required Wake Up Morning Leave For Work Day Return Home Evening Go To Bed Night Heating Program 6 00 AM 70 F 8 00 AM 62 F 5 00 PM 70 F 10 00 PM 62 F Cooling Program 6 00 AM 75 F 8 00 AM 83 F 5 00 PM 75 F 10 00 PM 78...

Page 12: ... on the terminal block allow connection of the remote sensor The thermostat must have 24 VAC Common connection to terminal C for the remote sensor to operate The remote sensor can be enabled or disabled in the Installer Configuration menu item 28 When remote sensor Remote is selected Off factory default no remote sensor is enabled When remote sensor is selected On the next step is to select the re...

Page 13: ...the dual fuel temperature setpoint menu item 33 can be set to a temperature of 5 through 50 When outdoor remote sensor is not installed a software logic based dual fuel number menu item 34 from 01 to 09 can be selected A higher temperature or dual fuel setting will provide a smaller stage separation between the heat pump and Aux to give more comfort A lower temperature or number will provide a lar...

Page 14: ... FAN Switch set to Fan ON Check each wire connection to verify they are not shorted or touching together No bare wire should stick out from under terminal block Try resetting the thermostat as de scribed above If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replac...

Reviews: