background image

Description

Gas or Oil Heat

Yes

Electric Furnace

Yes

Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Pump (with Aux. or Emergency Heat)

No

Systems with up to 3 Stages Heat, 2 Stages Cool

No

Heat Only Systems

Yes

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

Cool Only Systems

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

www.white-rodgers.com

Blue Selecto Thermostat with 

Automatic Heat/Cool Changeover Option

PART NO. 37-6952B

Replaces 37-6952A

0905

Single Stage or Heat Pump

Installation and Operating Instructions for Model:

APPLICATIONS 

THERMOSTAT APPLICATION GUIDE

1F80ST-0471 Thermostat

with Spanish Display

SPECIFICATIONS 

Electrical Rating:
 

Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . .    mV to 30 VAC, NEC Class II, 50/60 Hz or DC

 

Input-Hardwire  . . . . . . . . . . . . . . . . . . . . . . . . .    20 to 30 VAC

Terminal Load  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range  . . . . . . . . . . . . . . . . . . . . . . . . . . . .    45° to 90°F (7° to 32°C)
Differential (Single Stage)  . . . . . . . . . . . . . . . . . . . .    Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump)  . . . . . . . . . . . . . . . . . . . . .    Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient. . . . . . . . . . . . . . . . . . . . . . . . . .    32° to +105°F (0° to +41°C)
Operating Humidity  . . . . . . . . . . . . . . . . . . . . . . . . .    90% non-condensing max.
Shipping Temperature Range  . . . . . . . . . . . . . . . . .    -40° to +150°F (-40° to +65°C)
Dimensions Thermostat. . . . . . . . . . . . . . . . . . . . . .    3.4"H x 4.4"W x 1.3"D

CAUTION

!

To  prevent  electrical  shock  and/or  equipment  damage, 
disconnect electric power to system at main fuse or circuit 
breaker box until installation is complete.

ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this 
product may replace a product that contains mercury.

Mercury and products containing mercury must not be 
discarded in household trash. Do not touch any spilled 
mercury. Wearing non-absorbent gloves, clean up any 
spilled mercury and place in a sealed container. For proper 
disposal of a product containing mercury or a sealed 
container of spilled mercury, place it in a suitable shipping 
container. Refer to www.white-rodgers.com for location to 
send product containing mercury.

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS 
CAREFULLY BEFORE INSTALLING OR OPERATING THIS 
CONTROL COULD CAUSE PERSONAL INJURY AND/OR 
PROPERTY DAMAGE.

Model

Programming Choices

1F80ST-0471

5/2 Day

5/1/1 Day

Non-Programmable

1F86ST-0471

Non-Programmable

Save these instructions for future use!

Index

Page

Installation

2

Wiring Connections

3

Thermostat Quick Reference

3

Installer Confi guration Menu

4

Operating Your Thermostat 

6

Programming

6

Troubleshooting 

8

Summary of Contents for 1F86ST-0471

Page 1: ...ng max Shipping Temperature Range 40 to 150 F 40 to 65 C Dimensions Thermostat 3 4 H x 4 4 W x 1 3 D CAUTION To prevent electrical shock and or equipment damage disconnect electric power to system at main fuse or circuit breaker box until installation is complete ATTENTION MERCURY NOTICE This product does not contain mercury However this product may replace a product that contains mercury Mercury ...

Page 2: ...ll for heat but will power the circulator on a call for cool If your system requires that the thermostat power the circula tor fan on a call for heat this switch should be set to the ELEC position Typically gas and oil heating systems do not require the thermostat to power the circulator fan during a call for heat If your heat is gas or oil the switch should be set to the GAS position When the the...

Page 3: ...Temporal RETENER is displayed when the thermostat is in a Temporal RETENER Temporary Hold mode 3 Displays Cambiar Frio Change Filter when the system has run for the programmed filter time period as a reminder to change or clean your filter 4 Displays Ajuste Set for setpoint when in Run Program mode 5 Displays System Mode Calor Frio Auto Off or Hora Time in menu mode 6 Displays Fan Mode On Auto or ...

Page 4: ...ser to the displayed temperature to a maximum number of degrees selected Adjusting the setpoint temperature over a long cooling run time allows the system to reach your set temperature and turn off The room temperature will actually be higher than the thermostat displays but the reduction in humidity will allow comfort at the slightly higher temperature When Frio Ahorro is making adjustments Save ...

Page 5: ... five minutes 9 System Mode Configuration This thermostat is configured for Calor and Frio with Auto changeover SISTEMA switch with Frio Off Calor Auto default It can also be configured for Calor and Frio Frio Off Calor Calor only with fan Off Calor Calor only without fan Auto only Auto Off and Frio only Frio Off 10 Select Backlight Display The display backlight improves display contrast in low li...

Page 6: ...ram press Arrancar Programa If the SISTEMA button is pressed to select Auto the thermostat will change to Heat or Cool whichever ran last If it switches to heat but you want cool or it changes to cool but you want heat press both and buttons simultaneously to change to the other mode Set Current Time and Day 1 Press Menu and then Hora button once The display will show the hour only 2 Press and hol...

Page 7: ...llowing guidelines in mind when planning your program In Heating lower temperatures will save energy In Cooling higher temperatures will save energy If you plan on using Auto Changeover do not program the heating higher than the cooling PROGRAMMING For Programmable Model Only Wake Up Period 1 Leave For Work Period 2 Return Home Period 3 Go To Bed Period 4 Heating Program 6 00 AM 70 F 8 00 AM 62 F ...

Page 8: ...y resetting the thermostat as described above If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Thermostat Setting ThermostatThermometer Disagree 1 Thermostat thermometer setting requires adjustment The thermometer can be adjusted 4 degrees Se...

Reviews: