background image

3

1.)

  Gas/Elec Switch

 

If the system is a heat pump or electric furnace, the GAS/ELEC Switch must be set to 

Elec. If your system is a gas or oil furnace, the switch must be set to Gas

2.

)  O/B Terminal Switch

 

The O/B switch on this thermostat is factory set to the O position. This will accommodate 

the majority of heat pump applications, which require the changeover relay to be 

energized in Cool. If the heat pump being installed requires a B terminal, to energize the 

changeover relay in Heat, the O/B switch must be moved to the B position. 

3.)

  RC/RH Jumper Wire 

 

This thermostat electrically connects the RC and RH terminals so a jumper wire is not 

required. If the application provides a separate wire for RC and RH, clip the RC/RH 

jumper. This will isolate both terminals so they can be independently used. 

INSTALLER MENU

To prevent changes that may affect system performance, this thermostat has an INSTALLER’S 

MENU and an USER MENU. The INSTALLER’S MENU provides access to every option, while 

the USER MENU provides access to items that will not affect system performance. To access 

the INSTALLER’S MENU press the Menu button for 8 seconds. The display will show item 

30

 in 

the table below. Use Next and Back to navigate through menu items. Press   or   to change 

a menu setting. 

Installer’s Menu #

(Hold Menu 8 Seconds) 

Description

Default Setting 

(flashing icons)

Settings 

(Press   or )

30    

Heat Cycle Rate (how often  

the heat will turn on)

MEd

SLO – slow

MEd – medium

FAS – fast

35 

Cool Cycle Rate (how often  

the cooling will turn on)

MEd

SLO – slow

MEd – medium

FAS – fast

50     

Compressor Lockout 

(protects the compressor  

from short cycling) 

OFF

On – 

5

 minute display 

OFF – no delay 

65

Maximum Heat Limit 

(maximum set point for heat mode) 

99

47 

to 

99

66

Minimum Cool Limit (minimum 

set point for cool mode) 

45

45 

to 

97

74        

Schedule Type (set as either 

7

-Day, 

5-1-1

 Day or Non-Programmable) 

5

7 – 7

 Day

5 – 5-1-1 

Day

0

 – Non Programmable 

(Installer Menu continued on next page)

1

3

2

Battery Location

Premium AA alkaline batteries 

are required when C-wire is 

not available. When C-wire is 

available, the batteries provide 

a back-up source of power (this 

will maintain the clock in the 

event of a power outage).

4

Installer’s Menu #

(Hold Menu 8 Seconds) 

Description

Default Setting 

(flashing icons)

Settings 

76 

 

    

Early Start (starts heating or 
cooling early so your programmed 
temperature is reached by the 
programmed time)

OFF

On – start early 
OFF – start at program 
period time 

79

Fahrenheit or Celsius 

°F

°F – Fahrenheit
°C – Celsius 

81

       

Temperature Display 
Adjustment 
(adjust the displayed 
“Room Temperature”)

0

-5 to +5 

83

Continuous Display Light (keep 
the backlight always on – “C” wire 
required)

OFF

On  – always on
OFF – momentarily

 

86

Change Air Filter (set up a 
monthly reminder)

OFF

1 to 12 –

  reminder  time      

                (months)
OFF – no filter reminder

 

99    

Keypad Lock (prevent unwanted 
changes to the thermostat)

OFF

On  – disable buttons
OFF – all buttons are     
             active  

INSTALLER MENU (C0ntinued)

TEST EQUIPMENT

Turn on power to the system. 
Fan Operation 

If your system does not have a G terminal connection, skip to Heating System

1.)

  Move fan switch to On position. The blower should begin to operate. 

2.)

  Move fan switch to Auto position. The blower should stop immediately. 

Heating System

1.)

  Move System Switch to Heat position. 

2.)

 Press   to adjust thermostat setting to 

1° 

above room temperature. The system should 

begin to operate and the thermostat will indicate Heat On

3.) 

Press 

 

to adjust thermostat setting 

1° 

below room temperature. The heating system 

should stop operating and the thermostat should indicate Heat. 

Cooling System

1.)

   Move System Switch to Cool position. 

2.) 

Press   to adjust thermostat setting 

1° 

below room temperature. The blower should 

come on immediately on high speed, followed by cold air circulation. The thermostat will 

indicate Cool On. There can be up to a 

5

 minute delay. (see INSTALLER MENU, item

 50) 

3.) 

Press   to adjust thermostat setting to 

1° 

above room temperature. The cooling system 

should stop operating and the thermostat will indicate Cool.  

Note: If Starting Soon is shown on the display, the compressor lockout feature is operating. 

There will be up to a 

minute delay before the compressor turns on.(see INSTALLER MENU, 

item 

50

)

CAUTION

!

To prevent compressor and/or property damage, if the outdoor temperature is below 

50°

F, 

DO NOT operate the cooling system. 

Do not allow the compressor to run unless the compressor oil heaters have been operational 

for 

hours and the system has not been operational for at least 

5

 minutes. 

Summary of Contents for 1F83C-11PR

Page 1: ...disposing of products containing mercury Optional Accessory Wall Cover Up Plate F61 2663 6 3 4 W x 4 1 2 H 2 Terminal Designations Terminal Function RC Power for Cooling RH Power for Heating O B ChangeoverTerminal Energized in Heat B or Cool O for Heat Pump or Damper Systems Y Cooling Relay G Fan Relay W Heating Relay C Common wire for 24V optional with batteries When both RC and RH wires are pres...

Page 2: ...clock in the event of a power outage 4 Installer s Menu Hold Menu 8 Seconds Description Default Setting flashing icons Settings 76 Early Start starts heating or cooling early so your programmed temperature is reached by the programmed time OFF On start early OFF start at program period time 79 Fahrenheit or Celsius F F Fahrenheit C Celsius 81 Temperature Display Adjustment adjust the displayed Roo...

Page 3: ...as a 7 Day or Non Programmable thermostat refer to the User Menu above HoldTemperature bypassing the schedule With the System switch set to Heat or Cool momentarily press the Hold button Hold will be displayed Use or to adjust the temperature The thermostat will hold the room temperature at the selected setting until you press Run to start program operation again Program Override Temporary Hold Pr...

Page 4: ...stat should be reset by removing the batteries for 2 minutes This reset will not change the menu settings or program If the condition persists after reinstalling the batteries replace the thermostat To conveniently reset only the schedule and user settings back to factory defaults press Menu and Backlight buttons at the same time and hold until the display goes blank and resets Symptom Possible Ca...

Reviews: