User manual MPPT Solar charge controller PowerXtreme XS20
E18-XS20-EN00
www.emergoplus.com
Page 36 of 44
Under voltage
warning voltage
12.0V
12.0V
12.0V
—
—
9 - 17V
Undervoltage
shutdown voltage
11.1V
11.1V
11.1V
11.1V
9 - 17V
Discharge voltage
limit
10.6V
10.6V
10.6V
—
—
9 - 17V
About load time
delay
5s
5s
5s
—
—
1 - 30s
Equalizing charge
duration
120
minute
s
—
—
120
minute
s
—
—
0-600
minutes
Equalizing charge
interval
30 days 0 days
30
days
—
—
0 - 250
days (0
indicates
turning off
equalizing
charge
function)
Boost charge
duration
120
minute
s
120
minut
es
120
minute
s
—
—
10 - 600
minutes
If a user-defined battery is used, the default voltage parameters of the
system are the same as those of the sealed lead-acid battery. The
following logic must be followed when you modify battery charge and
discharge parameters: