manually check whether the load can be activated and deactivated
normally.
NOTE!
When a sine wave inverter is mounted into the
system, connect the inverter directly to the
battery, rather than to the controller output
terminals
NOTE!
In case no additional external temperature
sensor was connected to the controller, the
battery temperature will remain at 25°C.
NOTE!
Install the battery fuse as close to the battery
as possible. The distance should be no more
than 150 mm.
WARNING
When the battery poles have been connected the
wrong way around, the internal components of the
controller may get damaged within 10 minutes
after the charger has stopped charging.