9. [ ] If the Blades are configured as primary and standby, perform a failover test on the Blades in the
replacement enclosure.
If the Blades are not in a failover configuration, proceed to the next step.
a. Determine the Blade failover status using the command below and Table 3:
#
/nas/bin/nas_server -info –all
b. To test the failover configuration of the Blades in the replacement enclosure, type the following
command:
#
/nas/bin/server_standby <server_name> -activate mover
where
<server_name>
is the name of the primary Blade.
Use the
nas_server -list
command to get the server name.
c. After completing the failover, restore the primary Blade by typing the following command:
#
/nas/bin/server_standby <server_name> -restore mover
where
<server_name>
is the name of the primary Blade. Use the
nas_server -list
command to
get the server name.
Example:
In a two Blade system, Blade 2 has failed over to Blade 3, its standby. The command to restore Blade 2
as the primary Blade is:
#
/nas/bin/server_standby server_2 -restore mover
10. [ ] Verify the Blades have the correct mounts by entering the following commands for each Blade:
#
/nas/bin/server_mount <server_name>
where
<server_name>
is the name of the lowest-numbered Blade in the replacement BE.
Use the
nas_server -list
command to get the server name.
11. [ ] Check the fault LED on the front of the BE (
Figure 20
). If the fault LED is on, go to
FRU failures
for
information on how to resolve the problem.
Task 12: Installing the Blade Enclosure Front Bezel
The Blade enclosure front bezel must be installed into the Blade enclosure. To install the Blade enclosure
front bezel:
1. [ ] Carefully align the front bezel, by holding the bezel edges, to the two brackets on the front of the
enclosure.