Series
IZS31
Specific Product Precautions 1
Be sure to read this before handling.
Thread size
Recommended tightening torque
M3
0.61 to 0.63 N·m
M4
0.73 to 0.75 N·m
M5
1.3 to 1.5 N·m
Selection
Warning
1. This product is intended to be used with general
factory automation (FA) equipment.
If considering to use the product for other applications
(especially those stipulated in 4 on back page 1), consult with
SMC beforehand.
2. Use this product within the specified voltage and
temperature range.
Using outside of the specified voltage can cause a malfunction,
damage, electrical shock, or fire.
3. Use clean compressed air for fluid.
This product is not explosion proof. Never use a flammable
gas or an explosive gas as a fluid and never use this product
in the presence of such gases.
Contact us when fluids other than compressed air are used.
4. This product is not explosion-protected.
Never use this product in locations where the explosion of dust
is likely to occur or flammable or explosive gases are used.
This can cause fire.
Mounting
Warning
3. Do not use this product in an area where noise
(electric magnetic field or surge voltage, etc.) are
generated.
Using the ionizer under such conditions may cause it to
malfunction or internal devices to deteriorate or break down.
Take noise countermeasures and prevent the lines from
mixing or coming into contact with each other.
4. Observe the tightening torque requirements when
installing the ionizer. Refer to the following table
for tightening torques for screws, etc.
If overtightened with a high torque, the mounting screws or
mounting brackets may break.
Also, if under tightened with a low torque, the connection may
loosen.
Caution
5. Do not touch the electrode pin directly with
1. This product is not cleaned. When bringing into a
clean room, flush for several minutes and confirm
the required cleanliness before using.
Mounting
Warning
1. Reserve an enough space for maintenance, piping
and wiring
Please take into consideration that the one-touch fittings for
supplying air, need enough space for the air tubing to be easily
attached/detached.
To avoid excessive stress on the connector and one-touch
fitting, please take into consideration the air tubings minimum
bending radius and avoid bending at acute angles.
Wiring with excessive twisting, bending, etc. can cause
a malfunction, wire breakage, fire or air leakage.
Minimum bending radius: Power supply cable………35 mm
Sensor cable………………25 mm
(Note: Shown above is wiring with the fixed minimum allowable
bending radius and at a temperature of 20
°
C.
If used under this temperature, the connector can receive
excessive stress even though the minimum bending radius is
allowable.)
Regarding the minimum bending radius of the air tubing, refer to
the instruction manual or catalogue for tubing.
2. Mounting on a plane surface.
If there are irregularities, cracks or height differences, excessive
stress will be applied to the frame or case, resulting in damage
or other trouble. Also, do not drop or apply a strong shock.
Otherwise, damage or an accident can occur.
fingers or metalic tools.
If a finger is used to touch the electrode, it may get stuck or an
injury or electrical shock may occur from touching the
surrounding equipment.
In addition, if the electrode or cartridge is damaged with a tool,
the specification will not be met and damage and/or an
accident can occur.
Danger High Voltage!
Electrode needles are under high voltage. Never touch them as there
is a danger of electric shock or injury due to an evasive action
against a momentary electrical shock caused by inserting foreign
matter in the electrode cartridge or touching the electrode needle.
6. Do not affix any tape or seals to the main unit.
If the tape or seal contains any conductive adhesive
or reflective paint, a dielectric phenomenon may occur due
to ions arising from such substances, resulting in
electrostatic charging or electric leakage.
7. Installation and adjustment should be conducted
after turning off the power supply.