Step 10 Continued
Initialize the Storage System
2. Start the initialization utility:
•
HP-UX host
Open an
hpterm
window and enter
/opt/Navisphere/bin/naviinittool
•
Linux host
Open a console window and enter
/opt/Navisphere/bin/naviinittoolcli
•
NetWare client
From the toolbar, select
Start > Programs > EMC > Navisphere > Navisphere Storage System
Initialization
•
NetWare host
At a DOS prompt, enter
LOAD SYS:\EMC\NAVIINIT\NAVIINIT
•
Solaris host
Open a shell window and enter
/opt/Navisphere/bin/naviinittool
•
Windows host
From the toolbar, select
Start > Programs > EMC > Navisphere > Navisphere Storage System
Initialization
3. Read the license agreement and accept it by entering
y
for an HP-UX, Linux,
NetWare or Solaris host or clicking
I accept
and
Next
for a NetWare client or
Windows host.
The utility automatically scans the subnet for storage systems. When the
discovery operation is complete, the utility lists, by hardware serial number (see
page 16 for location of the serial number), all uninitialized and initialized
CLARiiON storage systems that it found. If the discovery operation did not find
the storage system that you are installing, verify that the storage system’s
management ports are properly cabled to the LAN on which the host resides. The
storage system and host must both reside on the same subnet.