![EMBRON HATTELAND TECHNOLOGY SeaHawk HT FBVF A-X1 Series User Manual Download Page 35](http://html.mh-extra.com/html/embron/hatteland-technology-seahawk-ht-fbvf-a-x1-series/hatteland-technology-seahawk-ht-fbvf-a-x1-series_user-manual_2399674035.webp)
35
IND101057-27
3 Feb. 2021
Hatteland Technology AS | www.hattelandtechnology.com | Enterprise no: NO974533146
Page 35 of 66
SNMP
Setup for using SNMP (Simple Network Management Protocol).It is compatible to both
SNMPv1 and SNMPvec. Settings for using SNMP are as following;
-
SNMP Listen Port (0, 161, 1025 ~ 65535)
The port is for connecting external device when system operates as a SNMP client.
SNMP is not used by setting 0 value.
-
SNMP Trap Destination IP
Set the SNMP Trap Destination IP.
-
SNMP Trap Destination Port (0, 162, 1025 ~ 65535)
Set the SNMP Trap Destination Port. SNMP is not used by setting 0 value.
-
SNMP Version
Select SNMP Version 1, 2C or 3
S
imple Network Management Protocol
(SNMP)
is used by network management systems to
communicate with network elements. SNMP lets TCP/IP-based network management clients
use a TCP/IP-based internetwork to exchange information about the configuration and status of
nodes. SNMP can also generate trap messages used to report significant TCP/IP events
asynchronously to interested clients. For example, a router could send a message if one of its
redundant power supplies fails or a printer could send an SNMP trap when it is out of paper