68
Operation Advanced (DDC/CI) Control Overview
IND100064-52
Description
Syntax and Functionality
Details and Values
Via SCOM
Touch Power Mode
(0xE6)
Write/Set Power Mode:
[S] <6E:w>
51 84 03
E6
00
xx
A1
[P]
Reply of successfull request:
[S] <6F:r>
5C 80 BE
*[P]
Read Power Mode:
[S] <6E:w>
51 82 01
E6
5A
[P]
Reply of successfull request :
[S] <6F:r>
6E 88 02 00
E6
01 00 FF 00
FF
53
*[P]
E6
= Command ID
Where
xx
is:
0x
FF
= Always Active
0x
FE
= Only active when display is
on and has an active input
signal
0x
00
= Only active if selected source
is active AND Selected
Source="DVI-I_1"*
0x
01
= Only active if selected source
is active AND Selected
Source="DVI-I_2"*
0x
02
= Only active if selected source
is active AND Selected
Source="DVI3"*
0x
03
= Only active if selected source
is active AND Selected
Source="DVI4"*
0x
10
= Only active if selected source
is active AND Selected
Source="RGB_1"*
0x
11
= Only active if selected source
is active AND Selected
Source="RGB_2"*
0x
12
= Only active if selected source
is active AND Selected
Source="RGB_3"*
0x
13
= Only active if selected source
is active AND Selected
Source="RGB_4"*
0x
20
= Only active if selected source
is active AND Selected
Source="CVIDEO1"
0x
21
= Only active if selected source
is active AND Selected
Source="CVIDEO2"
0x
22
= Only active if selected source
is active AND Selected
Source="CVIDEO3"
0x
23
= Only active if selected source
is active AND Selected
Source="CVIDEO4"
0x
30
= Only active if selected source
is active AND Selected
Source="DP1"
0x
31
= Only active if selected source
is active AND Selected
Source="DP2"
0x
32
= Only active if selected source
is active AND Selected
Source="DP3"
0x
33
= Only active if selected source
is active AND Selected
Source="DP4"
0x
3F
= Read Command
Read/Write support.
MCC:
(Touch Power
Mode)
Actual Temperature
(0xF0)
Read Temperature:
[S] <6E:w>
51 82 01
F0
4C
[P]
Reply of successfull request:
[S] <6F:r>
6E 88 02 00
F0
01
ww xx yy zz
63
*[P]
F0
= Command ID
Read support.
Reply 4 bytes (
ww, xx, yy, zz
)
indicating degree in Celcius.
Example: 0038
TMP
Unit Run Time
(0xF3)
Read Elapsed Hours:
[S] <6E:w>
51 82 01
F3
4F
[P]
Reply of successfull request:
[S] <6F:r>
6E 88 02 00
F3
01
ww xx yy zz
63
*[P]
F3
= Command ID
Read support.
Reply in ASCII 4 bytes
(
ww, xx, yy, zz
) indicating hours.
Example: 1038
ETC
Summary of Contents for HATTELAND TECHNOLOGY HD 43T22 MVD-MA C Series
Page 8: ...8 This page left intentionally blank...
Page 9: ...9 General...
Page 16: ...16 This page left intentionally blank...
Page 17: ...17 Installation...
Page 33: ...33 Operation...
Page 64: ...64 This page left intentionally blank...
Page 65: ...65 Operation Advanced DDC CI...
Page 69: ...69 Specifications...
Page 71: ...71 Technical Drawings...
Page 74: ...74 This page left intentionally blank...
Page 75: ...75 Technical Drawings Accessories...
Page 80: ...80 This page left intentionally blank...
Page 81: ...81 Appendixes...
Page 93: ...93 Appendix IND100077 24 User Notes...
Page 95: ...95 Revision History Appendix IND100077 198...
Page 96: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...