Probe use and maintenance
Probe must be always place in water vertically
•
Keep your probes electrode moist. Probes for new or long term storage should be placed in
protection cap with protective solution (which cover the glass electro). You should not remove
the cap before use. Keep the cap: place the probe back to the cap for long term storage.
• Make sure the pipe are fill with water during install and use the probe. The probe must be
electro must be in water always.
• Probe cannot install upside down or horizontally.
• When probe is in the pipe: make sure water in pipe does not freeze (especially during
Winter), it will damage the probe.
To have an accurate measure result, flow rate inside the pipe (with probe) must be in 2-10L.
4. PH AND ORP SETTING
Panel
SET LOW
Hysteresis
SET HIGH
CAL
ALARM LOW
ALARM HIGH
Set low ORP/
pH setpoint
Set hysteresis
Set High pH
setpoint
pH calibration
ORP/pH
Alarm low limit
ORP/pH
Alarm high limit
4.1 Functional setting
4.1.1
Power up:
Pull the power switch to “on”, LEDs will light up for 3 sec than display the real time value for
ORP and pH.
“ORP”digit display
Left Digit display is ORP, unit is in mV, which display ORP value and its related setting. Range
from 0-999.
“pH”digit display
Right Digit display is pH, unit is in pH, which display pH value and its related setting. Range
from 0-14.