SAFETY GUIDE 

 

IMPORTANT: The instruction manual you are holding includes essential information on the safety 
measures to be implemented for installation and start-up. Therefore, the installer as well as the 
user must read the instructions before beginning installation and start-up.   
Keep this manual for future reference. 

 
When using this electrical equipment, basic safety measures listed below should be followed: 

 

Disconnect all AC power during installation. 

 

To reduce the risk of injury, do not permit children to use this product unless they are closely supervised. 

 

A green colored terminal marked "Earth Ground" is located inside the wiring compartment. To reduce 
the  risk  of electric shock,  this  terminal  must be  connected  to the grounding  means provided in  the 
electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors 
supplying the equipment. 

 

To reduce the risk of electric shock, connect the local common bonding grid in the area of the swimming 
pool or spa to these terminals with an insulated or bare copper conductor. 

 
 

2.

 

CONTENTS OF PACKAGE 

 

Following components are contained in the package: 

 

SSCmini

®

 

Control unit 

SSCmini

®

 

Electrolytic Cell 

1.5” and 2” Universal Unions 

 
         
 
 
 
 
 
 
 
 
 

3.

 

SPECIFICATIONS 

 

Standard working voltage 

220-240 V AC – 50/60 Hz 

Maximum chlorine production 

20 g/h 

Maximum Pool Volume   

90 

 

Water salinity required 

4 – 6 g/l 

Working Temperature of Water 

10°C – 45°C (50°F – 113°F) 

Electrodes 

Titanium plates 

 

 

 

 

Summary of Contents for SSC mini

Page 1: ...1 SALT CHLORINATOR USER MANUAL SSCmini...

Page 2: ...side the wiring compartment To reduce the risk of electric shock this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equi...

Page 3: ...acteria the above reactions will continuously recycle virtually eliminating the need to add sanitizing chemicals to your pool The only time you may need to add more salt to the pool is when water is r...

Page 4: ...lkalinity 80 120 ppm Calcium Hardness 200 400 ppm Metal 0 ppm 6 1 SALT LEVEL The amount of salt required when using Emaux SSCmini is between 4000 and 6000 ppm To reach this concentration it is necessa...

Page 5: ...enclosure that is suitable for outdoor mounting IPX4 rating However the following points must be taken into consideration for a correct installation of the control unit 1 Install the Control Unit usi...

Page 6: ...ed in a vertical position 8 START UP Before starting up Emaux SSCmini unit the following points have to be taken into consideration 1 Check if the filter is completely clean and ensure that the swimmi...

Page 7: ...ng guide Chapter 12 3 Alarm The unit is not working properly Refer to the Troubleshooting guide Chapter 12 4 Stand by The unit is in between operation cycles 5 Normal operation Electrolytic cell is ge...

Page 8: ...LED is ON A new cycle will start at 10 00 until 10 30 and so on If you activate Superchlorination mode at 10 30 Superchlorination LED is ON then the unit will be working until 10 30 of the next day a...

Page 9: ...ebris which has passed through the filter and caught on the plates 3 Try to remove the scale using a plastic or wooden tool do NOT use metal as this will scratch the coating off the plates If the scal...

Page 10: ...pply Disconnect the unit from power supply for two minutes and then connect it again Ensure that SSCmini is receiving 220V 240VAC 50 60H input LED 4 Water temperature out of working range Test water t...

Page 11: ...equipment or installation type 4 Damage due to unauthorized product modifications or failure to use Emaux original replacement parts 5 Damage caused by negligence or failure to properly maintain produ...

Page 12: ...chnical operations Emaux is not liable for any loss of time inconvenience incidental expenses such as labor cost phone calls legal cost or material cost incurred in connection with the replacement or...

Reviews: