EM TEST
VDS 200 Series
Manual for Operation
V 5.19
6 / 57
Special models
Special models have the index VDS200N200
.x
. The difference to standard models is the voltage and current
ranges. The operation is the same as by the standard VDS equipment’s. The maximum overcurrent trips at the
rated current.
Model
voltage current
Inrush
Sinusfunction
f max
VDS 200N100.1
80V
I.
= 0A- 100A ± 10%
150A
500ms
VDS 200N100.3
30V
I.
= 0A- 100A ± 10%
150A
500ms
VDS 200N100.4
60V
I.
= 0A- 100A ± 10%
150A
500ms
Overvoltage protection
(selectable 20, 30, 40 and 60V)
VDS 200N100.5
60V
I.
= 0A- 100A ± 10%
150A
500ms
Extra fast slope
VDS 200N150.1
60V
I.
= 0A- 150A ± 10%
500A
200ms
VDS 200N200.1
60V
I
= 0A
– 200A ± 10%
450A
400ms
750A
200ms
1000A
100ms
30kHz
VDS 200N200.2
30V
I
= 0A
– 200A ± 10%
2000A
500ms
1Hz
– 20kHz
16Vpp
20kHz
– 30kHz 10Vpp
30kHz
– 50kHz 6Vpp
VDS 200N200.3
32V
I
= 0A
– 200A ± 10%
250A
500ms
VDS 200N200.4
30V
I
= 0A
– 200A ± 10%
1000A
500ms
Up VDS 200B5 S1
VDS200N100.3
VDS 200N100.4
VDS 200N200.3
VDS 200N200.4