EM TEST
VDS 200 Series
Manual for Operation
V 5.19
44 / 57
6.
Maintenance
6.1. General
The generator is absolutely maintenance-free by using a solid state semiconductor switch to generate the fast
transients.
6.2. Test set-up
When setting up the test national and international regulations regarding human
safety have to be guaranteed.
The test setup must be conform to the national and international regulations.
It is recommended to connect the simulator to the ground reference plane of the
test set-up.
The generators of the series 200, UCS, LD, PFS, VDS and AutoWave, can be
linked together to a fully automotive test set-up.
The set-up communicates via the IEEE/GPIB bus and is controlled by ISM ISO
software. For setting up the system see the following figures:
Each generator can be operated individual as a single equipment.
6.3. Test set-up with software iso.control
ATTENTION
Working with iso.control please connect VDS 200B to the PF1 input of PFS 200B
By using iso.control software :
Connect VDS with PF1 input.
Connect the external dc source ( controlled from PFS 200 ) on input PF2. Connect the analogue output from
PFS 200 to the external dc source.
As external dc source we propose a VDS 200, RDS 200 or an other dc source with an analogue dc input for
control.
With this set-up all DIPS and DROP
out tests are performed automatically
with iso.control software.