EM TEST
VDS 200 Series
Manual for Operation
V 5.19
38 / 57
5.5. General
Dimensions
Device
HU Unit
Dimension H x W x D
Weight
VDS 200N10,
6HE
28 x 45 x 40 cm
49 kg
VDS 200N15,
6HE
28 x 45 x 40 cm
49 kg
VDS 200N30
9HE
42 x 45 x 40 cm
69 kg
VDS 200N50
12HE
55 x 45 x 50 cm
114 kg
VDS 200N100
Minirack 15HE
85 x 55 x 60 cm
178 kg
VDS 200N100.2
Minirack 25HE
120 x 55 x 60 cm app 190 kg
VDS 200N100.3
Minirack 15HE
85 x 55 x 60 cm
148 kg
VDS 200N100.4
Minirack 20HE
107 x 55 x 60 cm
186 kg
VDS 200N100.6
Rack 32HU
183 x 55 x 80 cm
301 kg
VDS 200N150
Rack 35HE
195 x 60 x 80 cm
400 kg
VDS 200N200
Rack 34HE
190 x 60 x 80 cm
450 kg
VDS 200N200.1
Rack 34HU
196 x 60 x 80 cm
450 kg
VDS 200N30.1
Minirack 12HE
55 x 45 x 50 cm
65 kg
VDS 200N50.1
Minirack 20HE
112 x 55 x 60 cm
120 kg
VDS 200N50.1
208V
Minirack 20HE
112 x 55 x 80 cm
175 kg
VDS 200N200.3
Rack 25HU
129 x 55 x 80 cm
245 kg
VDS 200N200.4
Rack 34HU
196 x 60 x 80 cm
425 kg
Power supply as ordered
Depends on model
Single phase supply :
115V / 208V / 230V 50/60Hz
3 phase supply :
3x208V, 3x400V, 3x480V 50/60Hz
Fuses internal in VDS
All fuses slow blow type
Model / Line supply
115V
208V
230V
3x208V 3x400V 3x480V
VDS 200N10
60V 10A
2x 20A
2x 16A
2x 16A
VDS 200N15
60V 15A
2x 20A
2x 16A
2x 16A
VDS 200N30
60V 30A
2x 16A
2x 16A
VDS 200N50
60V 50A
3x 16A
3x 16A
VDS 200N100
60V 100A
3x 20A
3x 16A
VDS 200N100.2
40V 100A
3x 32A
VDS 200N100.3
30V 100A
1x16A
3x 25A
VDS 200N100.4
60V 100A
3x 32A
VDS 200N100.6
70V1200A
3x 25A
VDS 200N150
60V 150A
3x 32A
3x 25A
VDS 200N200
60V 200A
3x 35A
3x 32A
VDS 200N200.1
60V 200A
3x 35A
3x 32A
VDS 200N30.1
60V 30A
3x 16A
3x 16A
VDS 200N50.1
60V 50A
3x 20A
3x 20A
VDS 200N200.3
32V 200A
3x 63A
VDS 200N200.4
32V 200A
3x 63A