background image

EM-Technik GmbH - Industriestraße 2 - 67133 Maxdorf - Germany

[email protected]

www.em-technik.com

5

Material

PP

PVDF

PFA

Pressure Stage

PN 6

PN 6

PN 6

60°C

50%

50%

70%

70°C

40%

45%

60%

80°C

30%

40%

50%

90°C

20%

35%

45%

100°C

35%

40%

110°C

30%

35%

120°C

25%

30%

130°C

25%

30%

140°C

10%

25%

150°C

20%

160°C

15%

170°C

10%

180°C

10%

3.4 Measuring Ranges

•  Measuring ranges will be manufactured and calibrated 

according to the individual customer specifications. 

• 

To  order  following  information  are  required:  Medium, 

pressure, temperature, measuring range, viscosity and 

density.

4 Assembly and Operation

4.1 Assembly Instructions

• 

Make certain the fitting is suitable for the relevant ap

-

plication. The fitting must be suitable for the operating 

conditions of the pipeline system (medium, concentra

-

tion, temperature and pressure) as well as the relevant 

ambient conditions.

• 

Check the fitting for transport damage before installing 

it. If the fitting is damaged do not install it.

• 

The  planner,  the  construction  company  or  operating 

company are responsible for the positioning and instal-

lation of the fitting. Planning and installation errors can 

adversely affect the reliable functionality of the fitting 

and may represent a significant potential for hazard.

• 

After  the  fitting  is  installed  perform  a  tightness  and 

function check.

4.2 Tools Required

The tools required for installation and assembly are not 

included with delivery.

4.3 Connect Flow Meter

• 

The flow meter must be connected to the pipeline so it 

is free of mechanical stress.

• 

The  flow  meter  has  a  female  thread  (ISO,  DIN, 

ANSI) and can be connected with various connecting 

 

elements of the 

em

technik system.

• 

Observe the flow direction from the bottom to the top.

Cylindrical thread

Conical thread

Sealing is provided by a sealing collar for 

Cylindrical threads (G, M or UNF).

 

 A version with an O-ring is also possible.

Sealing is provided 

by the thread itself 

for Conical threads 

(NPT).

Sealing Collar

O-Ring

Thread

•  Each thread must always be connected with the same 

thread type.

• 

If a plastic fitting is used in combination with a metal

-

lic male fitting, additional sealing with Teflon® tape is 

 

recommended.

5 Commissioning

5.1 Precondition for Commissioning

•  Protect against leaks: Take protective measures 

against exceeding the maximum permitted pressure 

due to possible pressure surges.

• 

Check the tightness and function of the fitting.

• 

In new systems and after repairs, flush the line system 

to remove foreign materials.

5.2 Operation

The series 4Z flow meter has an integrated fine regula

-

ting valve. Turn the handwheel clockwise to reduce the 

flow. Turn the handwheel counter-clockwise to increase 

the flow.

5.3 Reading the Measured Value

• 

The  position  of  the  float  in  the  metering  tube  corre

-

sponds to the volumetric flow of the medium.

•  Parallax-free reading: Look over the top edge of the 

float and read the measured value on the scale.

Reviews: