6 Maintenance
•
When used as designated, the fitting is practically
wear-free and generally requires no maintenance.
• The operating company must perform regular visual
inspections of the fitting according to the operating
conditions to prevent leaks and damage.
7 Disposal
•
When disposing of the fitting and packaging, comply
with the relevant disposal requirements and environ-
mental protection regulations.
•
When disposing of fittings, pay careful attention to any
residues of toxic or corrosive media.
8 Return Delivery
Do not return before consulting with
em
technik.
1. Please consult with
em
technik.
2. Empty the fitting properly.
3. Rinse and clean the fitting thoroughly, especially if the
media is being conveyed are harmful, explosive, hot,
or hazardous in some other way.
4. For fittings that have been operated with aggressive,
corrosive, combustible, toxic or water polluting media,
a completely filled in clearance certificate must always
be included.
9 Troubleshooting /
Fault Rectification
Error
Possible
Cause
Error
Rectification
The fitting does not
open/close or not
completely
Foreign object in
the fitting
Flush the fitting
Connection between
fitting and pipeline is
leaking
Sealing surface
damaged
Use sealant,
see 4.3
Fitting is leaking
Fitting faulty
Check fitting for
damage and repla-
ce it if necessary
10 Manufacturer‘s Declaration
• Our products do not fall under the scope of the Ma-
chinery Directive 2006/42/EC. However, they can be
incorporated in an installation that is considered as
machinery. In this case regard the following note: The
products may not be put into operation until it is made
sure that the final machinery into which our products
are incorporated complies with the provisions of the
Machinery Directive 2006/42/EC.
•
Based on the fluid class, pressure and nominal diame
-
ter, our products fall under diagram 8 of the Pressure
Equipment Directive PED 2014/68/EU. Because of the
ratio of nominal diameter, pressure and volume, they
fall only under article 4 paragraph 3 and are designed
and manufactured according to applicable good engi-
neering practice. They must not carry any CE marking.
• The warranty of armature expires in the following ca-
ses: Operating conditions which do not follow the in-
tended use or do not follow technical specifications.
Improper installation or assembly. Just as well as inap-
propriate use, dismantling or modification.
• Failure to observe information provided here may lead
to injuries, material damage, malfunctions and impuri
-
ties due to escaping medium.
11 Contact
In case of questions or suggestions please contact us:
EM-Technik GmbH
Industriestr. 2
Tel +49 6237 407-0
67133 Maxdorf
Fax +49 6237 407-77
Germany
Version 06/2022