EMERGENCY RELEASE
Carry out only after power supply to the motor has been interrupted!
In the event of a power supply failure, release the gearmotor, so that you
can move the boom by hand.
To do so, use the ELVOX key supplied and turn it in the clockwise sense,
until the stop is reached (Pic. 12).
By doing so, the barrier boom works independent from the gearmotor and
it can be moved by hand.
When power is supplied again, turn the key counterclockwise strongly
until you block it.
MAINTENANCE
To be undertaken only by specialized staff after disconnecting
power supply.
After every 100.000 cycles check:
- boom balance (see the paragraph “ADJUSTING THE BALANCING
SPRINGS”);
- the tightness of the release knob (see the paragraph “EMERGENCY
RELEASE”);
- the tightness of the boom holding attachment and the implantation of
the boom (see the paragraph “ASSEMBLING THE BOOM”);
- the wear on the mechanical stops and the limiti switch setting (see the
paragraph “LIMIT SWITCH SETTING”).
- Grease the bearings of the boom carrier shaft and the threaded spring
guide bar.
The described maintenance is vital for the corrected operation of
the product in the time.
TR2
J10
J3
J5
J9
J1
J8
J7
J6
J4
S3
J2
Main power supply 230 Vac 50/60 Hz
Common contact
Closing limit switch contact (NC)
Opening limit switch contact (NC)
Closing slowing down limit switch contact (NO)
Opening slowing down limit switch contact (NO)
Vehicle presence signal (NO) (only when switched to PARK
mode)
Photocells contact (NC)
-
Common contact
Safety strip self-test power 12 Vdc 500 mA max
Accessories power 12 Vdc 500 mA max
Accessories power supply -12 Vdc 500 mA max
Barrier opening button 2 contact (NO) (only when switched to PARK mode)
Barrier open signal 12 Vdc
Buzzer - Acoustic signal connection (12 Vdc max 200 mA)
Radio antenna
Blinker (max 40 W)
Motor common connection
Motor inverters and condenser connection
Immediate closure command contact (only when switched to PARK mode)
Open1 button contact (NO)
Close button contact (NO)
Stop button contact (NC)
Single pulse button (NO)
Common contact (common line for all the commands and safety inputs)
-
Built-in radio module
-
DO NOT TOUCH THE JUMPER!
IF REMOVED THE OPERATOR DOES NOT FUNCTION!
DO NOT TOUCH THE JUMPER!
IF REMOVED THE RADIO SYSTEM DOES NOT FUNCTION!
Programming button
Slow closure speed electronic regulator
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
S3
TR2
L-N
COM
LSC
LSO
LSSC
LSSO
TLC
PHOT. NC
EDGE NC
COM
D+ TEST
D+
D-
OPEN 2
SIGNAL
AERIAL
U - MOTOR
V-W - MOTOR
OK CLOSE
OPEN 1
CLOSE
STOP
K BUTT.
COM
PROBE
RADIO
AUX. ATT.
SW PARK
SW RADIO
PROG.
TRIMMER LOW
SPEED
ELECTRIC CONNECTIONS
RS15
A
- CONTROL PANEL FEATURES
12
EN