www.prolight.co.uk
MP180 LED Fresnel RGBALC
User Manual
8
Operating instructions
Channel Value
Function
1
000-255 Master dimmer (0-100%)
1 channel mode:
Channel Value
Function
1
000-255 Red dimmer (0-100%)
2
000-255 Green dimmer (0-100%)
3
000-255 Blue dimmer (0-100%)
4
000-255 Amber dimmer (0-100%)
5
000-255 Lime dimmer (0-100%)
6
000-255 Cyan dimmer (0-100%)
6 channel mode:
Channel Value
Function
1
000-255 Hue
2
000-255 Saturation
3
000-255 Intensity
4
000-005 No function
006-255 CCT (2800-8000K)
5
000
No function
001-255 Tint (100-0-100%)
001 - magenta
128 - neutral
255 - green
5 channel mode:
Channel Value
Function
1
000-255 Master dimmer (0-100%)
2
000-255 Dimmer fine (0-100%)
3
000-005 LED on
006-255 Strobe (slow-fast)
4
000-255 Red dimmer (0-100%)
5
000-255 Green dimmer (0-100%)
6
000-255 Blue dimmer (0-100%)
7
000-255 Amber dimmer (0-100%)
8
000-255 Lime dimmer (0-100%)
9
000-255 Cyan dimmer (0-100%)
10
000-005 No function
006-255 CCT (2800-8000K)
11
000
No function
001-255 Tint (100-0-100%)
001 - magenta
128 - neutral
255 - green
12
000-255 Hue
13
000-255 Saturation
14
000-255 Intensity
15
000-005 No function
006-063 Linear dimmer curve (hold 3s)
064-127 Square dimmer curve (hold 3s)
128-191 I-Square dimmer curve (hold 3s)
192-255 S-Curve dimmer curve (hold 3s)
16
000-005 No function
006-063 LED dimmer mode (hold 3s)
064-127 Halogen dimmer mode (hold 3s)
128-255 No function
16 channel mode:
Master/slave mode:
To set the master unit, put the fixture into manual/HSI/CCT mode.
To set the other units in slave mode, press the
“MENU”
button and use the
“UP”
and
“DOWN”
buttons to
show
“SLAVE MODE”
on the LCD display. Press the
“ENTER”
button to confirm the setting. The unit will
now run in sequence with the master unit.
To exit out of any of the above options, press the
“MENU”
button.
Please ensure that all slave units are set to the same DMX channel mode as the master unit.