background image

www.prolight.co.uk

MP180 LED Fresnel RGBALC

  

User Manual

2

Safety advice

WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not connect this equipment to a dimmer pack.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available mains supply voltage is 

between 110~240V AC, 50/60Hz.

•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again. 
 

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Pro Light 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  This lighting fixture is for professional use only - it is 

not designed for or suitable for household use. The 
product must be installed by a qualified technician in 
accordance with local territory regulations. The safety of 
the installation is the responsibility of the installer. The 
fixture presents risks of severe injury or death due to fire 
hazards, electric shock and falls.

•  Warning! Risk Group 2 LED product according to 

EN 62471. Do not view the light output with optical 
instruments or any device that may concentrate the beam.

•  WARRANTY: Two years from date of purchase.

Summary of Contents for MP180 LED Fresnel RGBALC

Page 1: ...Order code ELUM112 MP180 LED Fresnel RGBALC User Manual ...

Page 2: ...off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 110 240V AC 5...

Page 3: ...ight wherever needed The addition of amber lime and cyan within the LED source make for perfect colour mixing on any scene or subject These fixtures provide a superb light output and benefit from temperature controlled fan cooling for whisper quiet operation 1 x 180W six colour COB LED RGBALC Manually adjustable beam angle 13 46 13 6 849 Lux 2m 46 2 141 Lux 2m CRI 80 17kHz refresh rate DMX channel...

Page 4: ... Technical specifications 01 LCD display 02 Function buttons 03 Zoom knob 04 3 Pin DMX input 05 3 Pin DMX output 06 5 Pin DMX input 07 5 Pin DMX output 08 PowerCON input 09 PowerCON output 10 Fuse T3A 250V In the box 1 x fixture 1 x barn door 1 x PowerCON cable 1 x user manual 11 Barn doors 12 Hanging bracket 13 Hanging bracket adjustable knob 215mm 185mm 245mm 147mm 36mm 301mm 1 4 2 m m 318mm 450...

Page 5: ... 512 DIMCURVE DIMCURVE I Square DIMCURVE Square Dimmer Curves DIMCURVE S Curve DIMCURVE Linear CHANNEL CHANNEL 01CH CHANNEL 06CH CHANNEL 16CH DMX channel setting CHANNEL 05CH SLAVE MODE DIMMODE DIMMODE LED DIMMODE HALOGEN LED Halogen selection DIMCURVE Blackout DMX FAIL DMX FAIL Hold DMX FAIL Static Manual HSI CCT mode Hold last command Blackout ...

Page 6: ... 255 MANUAL G 255 MANUAL C 255 MANUAL A 255 MANUAL Dim 255 MANUAL B 255 MANUAL STR 000 MANUAL L 255 MANUAL R 255 MANUAL G 255 MANUAL C 255 MANUAL A 255 MANUAL B 255 MANUAL L 255 MANUAL DimF 000 Manual mode White balance 000 255 HSI HSI S 255 HSI I 255 HSI H 000 HSI mode 000 255 ClrTemp ClrTemp TINT 000 ClrTemp CCT 000 CCT mode ...

Page 7: ... Now press the ENTER button and use the UP and DOWN buttons to set the required DMX address Press the ENTER button to confirm the setting To access the DMX channel mode press the MENU button to show CHANNEL on the LCD display Now press the ENTER button and use the UP and DOWN buttons to set the required DMX channel Press the ENTER button to confirm the setting To choose what the fixture does when ...

Page 8: ... 100 8 000 255 Lime dimmer 0 100 9 000 255 Cyan dimmer 0 100 10 000 005 No function 006 255 CCT 2800 8000K 11 000 No function 001 255 Tint 100 0 100 001 magenta 128 neutral 255 green 12 000 255 Hue 13 000 255 Saturation 14 000 255 Intensity 15 000 005 No function 006 063 Linear dimmer curve hold 3s 064 127 Square dimmer curve hold 3s 128 191 I Square dimmer curve hold 3s 192 255 S Curve dimmer cur...

Page 9: ...DOWN buttons to set the Red Green Blue Amber Lime Cyan Strobe Dimmer and Dimmer Fine from 000 255 Press the ENTER button to confirm the setting 000 LED off 255 LED at full brightness 000 Strobe off 255 Strobe fast HSI mode To access HSI mode press the MENU button on to show HSI on the LCD display Press the ENTER button and use the UP and DOWN buttons to set the Hue Saturation and Intensity from 00...

Page 10: ...isplay The unit will now display the fixtures software version Fixture temperature To access the fixtures temperature press the MENU button and use the UP and DOWN buttons to show TEMP on the LCD display The unit will now display the fixtures temperature Factory reset To access factory reset press the MENU button on the rear of the unit to show FACTORY RESET on the LCD display Press the ENTER butt...

Page 11: ...owing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixt...

Page 12: ... a cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal 3 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C DMX setup Termination reduces signal tr...

Page 13: ... fixtures are connected a new power run will need to be started Please note Caution should be used when power linking other fixtures to the MP180 LED Fresnel RGBALC as the power consumption of other fixtures will vary Fixtures fitted with lamps often require 2 3 times more current on startup these may require their own power source POWER INPUT 100 240V 50 60Hz POWER CONSUMPTION 190W POWER OUTPUT 1...

Page 14: ...t possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environment...

Page 15: ...www prolight co uk MP180 LED Fresnel RGBALC User Manual 15 ...

Page 16: ...www prolight co uk MP180 LED Fresnel RGBALC User Manual 16 ...

Reviews: