background image

www.prolight.co.uk

MP 120 LED Fresnel WW

  

User Manual

5

Operating instructions

MENU

DMX MODE

DMX address setting

DMX MODE 

ADDR:001

DMX MODE 

ADDR:512

DMX FAIL

DMX FAIL

HOLD

DMX FAIL

BLACKOUT

Blackout if no DMX 
signal present

Hold last command

DIMCURVE

DIMCURVE 

Linear

DIMCURVE 

I-Square

DIMCURVE 

Square

Dimmer Curves

DIMCURVE 

S-Curve

CHANNEL

CHANNEL

1CH

 CHANNEL

5CH

DMX channel setting

CHANNEL

3CH

SLAVE

MODE

DIMMODE

DIMMODE 

LED

DIMMODE 

HALOGEN

LED/Halogen selection

MANUAL 

STR:000

Panel.Ctrl 

STR:255

MANUAL

MANUAL 

DIM:000

MANUAL 

DIM:255

Manual mode

TEMP

___ C/F

Soft Ver

V_.___

BACKLIG

BACKLIG

OFF

BACKLIG

ON

Backlight setting

FacReset

FacReset

No

FacReset

Yes

Factory reset

Summary of Contents for ELUM107

Page 1: ...Order codes ELUM107 Black Housing ELUM107A White Housing MP 120 LED Fresnel WW User Manual ...

Page 2: ...f in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 110 240V AC 50 ...

Page 3: ...ned in an array further enhancing their usage 1 x 120W warm white COB LED 3000K Manually adjustable beam angle 19 37 14 800 Lux 2m full on 1 5kHz refresh rate DMX channels 1 3 or 5 selectable 0 100 dimming and variable strobe 4 dimming curves in both LED and halogen profiles Linear square law inverse square law and S curve 4 push button menu with LCD display PowerCON input output 5 Pin XLR input o...

Page 4: ...4 05 06 07 01 08 Technical specifications 01 Earth point 02 LCD display 03 Function buttons 04 Function knobs 05 3 Pin DMX input 06 3 Pin DMX output 07 5 Pin DMX input 08 5 Pin DMX output 09 PowerCON input 10 PowerCON output In the box 1 x fixture 1 x barn door 1 x PowerCON cable 1 x user manual 11 Fuse T3A 250V 12 Barn doors 13 Hanging bracket 14 Hanging bracket adjustable knob ...

Page 5: ...mmand DIMCURVE DIMCURVE Linear DIMCURVE I Square DIMCURVE Square Dimmer Curves DIMCURVE S Curve CHANNEL CHANNEL 1CH CHANNEL 5CH DMX channel setting CHANNEL 3CH SLAVE MODE DIMMODE DIMMODE LED DIMMODE HALOGEN LED Halogen selection MANUAL STR 000 Panel Ctrl STR 255 MANUAL MANUAL DIM 000 MANUAL DIM 255 Manual mode TEMP ___ C F Soft Ver V_ ___ BACKLIG BACKLIG OFF BACKLIG ON Backlight setting FacReset F...

Page 6: ...TER button and use the UP and DOWN buttons to choose between HOLD or BLACKOUT Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Operating instructions Channel Value Function 1 000 255 Master dimmer 0 100 1 channel mode Channel Value Function 1 000 255 Master dimmer 0 100 2 000 255 Dimmer fine 0 100 3 000 005 LED on 006 255 Strobe slow fast ...

Page 7: ...DOWN buttons to set the dimmer from 000 255 Press the ENTER button and use the UP and DOWN buttons to set the strobe from 000 255 000 LED off 255 LED at full brightness 000 Strobe off 255 Strobe fast To exit out of any of the above options press the MENU button Backlight To access the backlight setting press the MENU button on the rear of the unit to show BACKLIG on the LCD display Press the ENTER...

Page 8: ...on on the rear of the unit to show FacReset on the LCD display Press the ENTER button and use the UP and DOWN buttons to select Yes Press the ENTER button to confirm the setting The fixture will reset to factory default settings To exit out of any of the above options press the MENU button Operating instructions ...

Page 9: ...ing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixtur...

Page 10: ...a cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal 3 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C DMX setup Termination reduces signal tra...

Page 11: ... the maximum number of fixtures are connected a new power run will need to be started Please note Caution should be used when power linking other fixtures to the MP 120 LED Fresnel WW as the power consumption of other fixtures will vary Fixtures fitted with lamps often require 2 3 times more current on startup these may require their own power source POWER INPUT 100 240V 50 60Hz POWER OUTPUT 100 2...

Page 12: ... possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmenta...

Reviews: