background image

www.prolight.co.uk

MP 120 LED Fresnel WW

  

User Manual

9

Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, 
105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in  
the chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output,  
see images below.

 
 
 
Also remember that DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote:

CABL10 – 2m

CABL11 – 5m

CABL12 – 10m

3-Pin:

CABL185 – 2m

CABL187 – 5m

CABL188 – 10m

5-Pin:

Summary of Contents for ELUM107

Page 1: ...Order codes ELUM107 Black Housing ELUM107A White Housing MP 120 LED Fresnel WW User Manual ...

Page 2: ...f in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 110 240V AC 50 ...

Page 3: ...ned in an array further enhancing their usage 1 x 120W warm white COB LED 3000K Manually adjustable beam angle 19 37 14 800 Lux 2m full on 1 5kHz refresh rate DMX channels 1 3 or 5 selectable 0 100 dimming and variable strobe 4 dimming curves in both LED and halogen profiles Linear square law inverse square law and S curve 4 push button menu with LCD display PowerCON input output 5 Pin XLR input o...

Page 4: ...4 05 06 07 01 08 Technical specifications 01 Earth point 02 LCD display 03 Function buttons 04 Function knobs 05 3 Pin DMX input 06 3 Pin DMX output 07 5 Pin DMX input 08 5 Pin DMX output 09 PowerCON input 10 PowerCON output In the box 1 x fixture 1 x barn door 1 x PowerCON cable 1 x user manual 11 Fuse T3A 250V 12 Barn doors 13 Hanging bracket 14 Hanging bracket adjustable knob ...

Page 5: ...mmand DIMCURVE DIMCURVE Linear DIMCURVE I Square DIMCURVE Square Dimmer Curves DIMCURVE S Curve CHANNEL CHANNEL 1CH CHANNEL 5CH DMX channel setting CHANNEL 3CH SLAVE MODE DIMMODE DIMMODE LED DIMMODE HALOGEN LED Halogen selection MANUAL STR 000 Panel Ctrl STR 255 MANUAL MANUAL DIM 000 MANUAL DIM 255 Manual mode TEMP ___ C F Soft Ver V_ ___ BACKLIG BACKLIG OFF BACKLIG ON Backlight setting FacReset F...

Page 6: ...TER button and use the UP and DOWN buttons to choose between HOLD or BLACKOUT Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Operating instructions Channel Value Function 1 000 255 Master dimmer 0 100 1 channel mode Channel Value Function 1 000 255 Master dimmer 0 100 2 000 255 Dimmer fine 0 100 3 000 005 LED on 006 255 Strobe slow fast ...

Page 7: ...DOWN buttons to set the dimmer from 000 255 Press the ENTER button and use the UP and DOWN buttons to set the strobe from 000 255 000 LED off 255 LED at full brightness 000 Strobe off 255 Strobe fast To exit out of any of the above options press the MENU button Backlight To access the backlight setting press the MENU button on the rear of the unit to show BACKLIG on the LCD display Press the ENTER...

Page 8: ...on on the rear of the unit to show FacReset on the LCD display Press the ENTER button and use the UP and DOWN buttons to select Yes Press the ENTER button to confirm the setting The fixture will reset to factory default settings To exit out of any of the above options press the MENU button Operating instructions ...

Page 9: ...ing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixtur...

Page 10: ...a cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal 3 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C DMX setup Termination reduces signal tra...

Page 11: ... the maximum number of fixtures are connected a new power run will need to be started Please note Caution should be used when power linking other fixtures to the MP 120 LED Fresnel WW as the power consumption of other fixtures will vary Fixtures fitted with lamps often require 2 3 times more current on startup these may require their own power source POWER INPUT 100 240V 50 60Hz POWER OUTPUT 100 2...

Page 12: ... possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmenta...