www.prolight.co.uk
MP 120 LED Fresnel WW
User Manual
6
DMX mode:
Operating in a DMX control mode environment gives the user the greatest flexibility when it comes
to customising or creating a show. In this mode you will be able to control each individual trait of the
fixture and each fixture independently.
To access the DMX address mode, press the
“MENU”
button on the front of the unit to show
“DMX MODE”
on the LCD display. Now press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons
to set the required DMX address. Press the
“ENTER”
button to confirm the setting.
To exit out of any of the above options, press the
“MENU”
button.
To access the DMX channel mode, press the
“MENU”
button on the front of the unit to show
“CHANNEL”
on the LCD display. Now press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons
to set the required DMX channel. Press the
“ENTER”
button to confirm the setting.
To exit out of any of the above options, press the
“MENU”
button.
To choose what the fixture does when it loses DMX signal, press the
“MENU”
button on the front of
the unit to show
“DMX FAIL”
on the LCD display. Now press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons to choose between
“HOLD”
or
“BLACKOUT”
.
Press the
“ENTER”
button to confirm the setting.
To exit out of any of the above options, press the
“MENU”
button.
Operating instructions
Channel Value
Function
1
000-255 Master dimmer (0-100%)
1 channel mode:
Channel Value
Function
1
000-255 Master dimmer (0-100%)
2
000-255 Dimmer fine (0-100%)
3
000-005 LED on
006-255 Strobe (slow-fast)
4
000-005 No function
006-063 Linear dimmer curve (hold 3s)
064-127 Square dimmer curve (hold 3s)
128-191 I-Square dimmer curve (hold 3s)
192-255 S-Curve dimmer curve (hold 3s)
5
000-005 No function
006-063 LED dimmer mode (hold 3s)
064-127 Halogen dimmer mode (hold 3s)
128-255 No function
5 channel mode:
Channel Value
Function
1
000-255 Master dimmer (0-100%)
2
000-255 Dimmer fine (0-100%)
3
000-005 LED on
006-255 Strobe (slow-fast)
3 channel mode:
Master/slave mode:
To set the master unit, put the fixture into manual mode.
To set the other units in slave mode, press the
“MENU”
button and use the
“UP”
and
“DOWN”
buttons to
show
“SLAVE MODE”
on the LCD display. Press the
“ENTER”
button to confirm the setting. The unit will
now run in sequence with the master unit.
To exit out of any of the above options, press the
“MENU”
button.
Please ensure that all slave units are set to the same DMX channel mode as the master unit.