Operating instructions

Channel

Value

Function

CH7

000-003

Open

004-007

Static gobo 1

008-011

Static gobo 2

012-015

Static gobo 3

016-019

Static gobo 4

020-023

Static gobo 5

024-027

Static gobo 6

028-035

Static gobo 7

036-039

Static gobo 8

040-043

Static gobo 9

044-047

Static gobo 10

048-051

Static gobo 11

052-055

Static gobo 12

056-059

Static gobo 13

060-063

Static gobo 14

064-067

Static gobo 15

068-071

Static gobo 16

072-079

Static gobo 17

080-083

Gobo 1 shake (slow-fast)

084-087

Gobo 2 shake (slow-fast)

088-091

Gobo 3 shake (slow-fast)

092-095

Gobo 4 shake (slow-fast)

096-099

Gobo 5 shake (slow-fast)

100-103

Gobo 6 shake (slow-fast)

104-107

Gobo 7 shake (slow-fast)

108-111

Gobo 8 shake (slow-fast)

112-115

Gobo 9 shake (slow-fast)

116-119

Gobo 10 shake (slow-fast)

120-123

Gobo 11 shake (slow-fast)

124-127

Gobo 12 shake (slow-fast)

128-131

Gobo 13 shake (slow-fast)

132-135

Gobo 14 shake (slow-fast)

136-139

Gobo 15 shake (slow-fast)

140-143

Gobo 16 shake (slow-fast)

144-159

Gobo 17 shake (slow-fast)

160-207

Gobo wheel scroll CW  
(fast-slow)

208-255

Gobo wheel scroll CCW  
(slow-fast)

16 channel mode cont.:

Channel

Value

Function

CH8

000-007

Blackout

008-015

Open

016-131

Strobe (slow-fast)

132-139

Open

140-181

Strobe (slow open, fast close)

182-189

Open

190-231

Strobe (fast open, slow close)

232-239

Open

240-247

Random Strobe (slow-fast)

248-255

Open

CH9

000-255

Dimmer (0-100%)

CH10

000-007

No function

008-255

4 facet circular prism

CH11

000-127

Prism indexing

128-191

Prism rotation CCW (fast-slow)

192-255

Prism rotation CW (slow-fast)

CH12

000-007

No function

008-255

16 facet circular prism

CH13

000-127

Prism indexing

128-191

Prism rotation CCW (fast-slow)

192-255

Prism rotation CW (slow-fast)

CH14

000-007

No function

008-255

Frost

CH15

000-255

Focus

Summary of Contents for 9RE Beam

Page 1: ...Order codes ELUM016 9RE Beam User Manual ...

Page 2: ... life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 60Hz Make sure that the power cable is never crimped ...

Page 3: ...surfaces must be equal to or greater than 12 meters 40ft CAUTION If the lens gets damaged ie cracks or deep scratches so the output is impaired then it must be replaced CAUTION The maximum ambient temperature Ta of 40 must not be exceeded CAUTION The lamp must be replaced if damaged or deformed CAUTION Turning the fixture on and off in short intervals will reduce the lamp life CAUTION To avoid dam...

Page 4: ... Specifications 9RE Beam Power consumption 340W Fuse F3A 250V Power supply 100 240V 50 60Hz Dimensions 469 x 337 x 243mm Weight 15 6kg Order code ELUM016 0m 5m 10m 15m 20m 2 5 Lux 804000 201000 89300 50300 2 5 The powerful 9RE Beam moving head allows users to create sharp well defined 2 5 beams powered by an MSD 260R9 8000K discharge lamp The fixture not only has superb optics and motorised focus ...

Page 5: ...www prolight co uk 9RE Beam User Manual 5 270mm 408mm 469mm 456mm Technical specifications 108mm 243mm 290mm 332mm 337mm 211mm 120mm ...

Page 6: ...D display 02 Function buttons 03 3 Pin DMX input 04 3 Pin DMX output 05 5 Pin DMX input 06 5 Pin DMX output 07 PowerCON input 08 PowerCON output 09 Fuse F3A 250V 10 Fans In the box 1 x fixture 2 x omega clamps 1 x power cable 1 x user manual 10 07 03 04 06 01 02 05 08 09 10 ...

Page 7: ...iodic safety inspections of the fixture and installation material If you do not have the relevant experience and or qualifications please do not attempt the installation yourself The installation should be checked annually by a qualified person The eLumen8 9RE Beam can be operated in a number of mounting positions as shown in the diagram above hanging upside down from the ceiling or truss mounting...

Page 8: ...p quick lock fasteners with the respective holes on the bottom of the unit 3 Tighten both locking fasteners clockwise on each omega clamp ensuring they re fully secure 4 Mount the fixture onto your truss system via the clamps and tighten to ensure secure 5 Pull the safety cable through the safety cable holes located on the metal base plate on the underside of the fixture and around the truss 1 2 4...

Page 9: ...light co uk 9RE Beam User Manual 9 Pan Tilt Lock Mechanism LOCKED UNLOCKED 9 0 9 0 9 0 9 0 Pan mechanism lock and release every 90 LOCKED UNLOCKED 45 4 5 4 5 45 4 5 4 5 Tilt mechanism lock and release every 45 ...

Page 10: ... with older lamps The lamp must be replaced at the end of its recommended duty cycle Extreme caution should be taken when operating this or any fixture fitted with a discharge lamp Lamp replacement To ensure a safe lamp change please read the following instructions carefully The YODN MSD 260R9 Lamp MUST be replaced every 2000 hours or when damaged and or deformed When the lamp needs replacing the ...

Page 11: ...own Only use the recommended lamp Damages caused by not following the guidelines outlined in this manual are not subject to warranty Please follow the lamp manufacturers notes Warning Do not touch the lamp envelope with bare hands Should this happen the bulb must be cleaned with a cloth soaked in alcohol and dried once cleaned 6 Slide both Fastons 4 onto the lamp ensuring the correct wires are att...

Page 12: ... 4 screws on the lamp assembly plate labelled C Do not remove these totally a half turn will suffice 5 Move the lamp into the required position left right by using a suitable flat headed screwdriver inserted into the adjustment screw labelled D and rotate clockwise lamp moves left anti clockwise lamp moves right until the lamp has been adjusted to your requirements 6 Tighten the 4 screws on the la...

Page 13: ...rection of the hotspot to centralise it Please see diagram below Image on the wall Move the lamp to the right Image on the wall Move the lamp to the left Please note The adjusted hotspot may move during the first 100 hours of lamp operation as the lamp stabilises whilst its burning Please adjust the lamp if the hotspot moves out of the centre ...

Page 14: ...ub menu where you can use the LEFT and RIGHT buttons to select option value required Once the option value has been selected press the ENTER button once more to confirm the setting To exit out of any of the above options press and hold the MENU button The LCD control panel can be used via the internal battery To access this press and hold the DISPLAY BACKUP button for 5 seconds until the fixtures ...

Page 15: ...o confirm the setting Main Menu Defaults are in grey DMX channel mode To access the DMX channel mode press the MENU button on the front of the unit to show Channel Mode on the LCD display Now press the ENTER button and use the UP and DOWN buttons to set the required DMX channel Press the ENTER button to confirm the setting DMX fail Sets what the fixture does when the DMX signal is lost To access t...

Page 16: ...er Manual Control Gobo Manual Control Colour Manual Control Prism Manual Control PrismR Manual Control Prism 2 Manual Control Prism 2R Manual Control Focus Manual Control Frost Operating instructions Manual control To access manual control mode press the MENU button on to show Manual Control on the LCD display Press the ENTER button and use the UP and DOWN buttons to select the various options Pre...

Page 17: ...the MENU button on to show Tilt Inverse on the LCD display Press the ENTER button and use the UP and DOWN buttons to select between No and Yes Press the ENTER button to confirm the setting Lamp On To switch the lamp on To access the lamp setting press the MENU button on to show Lamp On on the LCD display Press the ENTER button and use the UP and DOWN buttons to select between Off and On Press the ...

Page 18: ...g press the MENU button on to show On If DMX On on the LCD display Press the ENTER button and use the UP and DOWN buttons to select between Off and On Press the ENTER button to confirm the setting Off if DMX off Sets whether the lamp is switched off when disconnected from DMX To access the off if DMX off setting press the MENU button on to show Off If DMX Off on the LCD display Press the ENTER but...

Page 19: ...ng colour To access the blackout whilst colour change setting press the MENU button on to show BL O Colour on the LCD display Press the ENTER button and use the UP and DOWN buttons to select between Off and On Press the ENTER button to confirm the setting Blackout whilst gobo change Sets whether the fixture blacks out whilst changing gobo To access the blackout whilst gobo change setting press the...

Page 20: ... Press the ENTER button the fixture will perform the auto test Fixture temperature Displays the fixture temperature To display the fixtures temperature press the MENU button and use the UP and DOWN buttons to show Temp on the LCD display The unit will now display the fixtures temperature Fixture Time Displays the fixtures total run time To display the fixtures total run time press the MENU button ...

Page 21: ...when yes is selected Factory Settings Resets all the fixtures factory settings To access the factory setting reset press the MENU button on to show Factory Settings on the LCD display Press the ENTER button and use the UP and DOWN buttons to select between No and Yes Press the ENTER button to perform the factory setting reset when yes is selected Lamp Time cont To clear the lamps total usage time ...

Page 22: ...m2 Offset Frost Offset Focus Operating instructions Offset Menu Calibration settings for the fixture To access the units offset menu press the MENU button once to display DMX Address on the LCD display Press and hold the ENTER button until the offset menu is displayed Use the UP and DOWN buttons to select the various options Press the ENTER button and use the UP and DOWN buttons to select between ...

Page 23: ...35 Pan Tilt Macro 16 136 143 Pan Tilt Macro 17 144 151 Pan Tilt Macro 18 152 159 Pan Tilt Macro 19 160 167 Pan Tilt Macro 20 168 175 Pan Tilt Macro 21 176 183 Pan Tilt Macro 22 184 191 Pan Tilt Macro 23 192 199 Pan Tilt Macro 24 200 207 Pan Tilt Macro 25 208 215 Pan Tilt Macro 26 CH4 cont 216 223 Pan Tilt Macro 27 224 231 Pan Tilt Macro 28 232 239 Pan Tilt Macro 29 240 247 Pan Tilt Macro 30 248 25...

Page 24: ...o 10 shake slow fast 120 123 Gobo 11 shake slow fast 124 127 Gobo 12 shake slow fast 128 131 Gobo 13 shake slow fast 132 135 Gobo 14 shake slow fast 136 139 Gobo 15 shake slow fast 140 143 Gobo 16 shake slow fast 144 159 Gobo 17 shake slow fast 160 207 Gobo wheel scroll CW fast slow 208 255 Gobo wheel scroll CCW slow fast 16 channel mode cont Channel Value Function CH8 000 007 Blackout 008 015 Ope...

Page 25: ... colour changing 069 085 Disable blackout whilst colour changing 086 102 Enable blackout whilst gobo changing 103 119 Disable blackout whilst gobo changing 120 136 Enable blackout whilst pan tilt gobo colour change 137 153 Disable blackout whilst pan tilt gobo colour change 154 170 No function 171 187 Lamp On 188 204 Lamp Off 205 221 No function 222 238 Motor reset hold for 5 seconds 239 255 No fu...

Page 26: ...8 135 Pan Tilt Macro 16 136 143 Pan Tilt Macro 17 144 151 Pan Tilt Macro 18 152 159 Pan Tilt Macro 19 160 167 Pan Tilt Macro 20 168 175 Pan Tilt Macro 21 176 183 Pan Tilt Macro 22 184 191 Pan Tilt Macro 23 192 199 Pan Tilt Macro 24 200 207 Pan Tilt Macro 25 208 215 Pan Tilt Macro 26 216 223 Pan Tilt Macro 27 224 231 Pan Tilt Macro 28 232 239 Pan Tilt Macro 29 240 247 Pan Tilt Macro 30 248 255 Pan ...

Page 27: ... 123 Gobo 11 shake slow fast 124 127 Gobo 12 shake slow fast 128 131 Gobo 13 shake slow fast 132 135 Gobo 14 shake slow fast 136 139 Gobo 15 shake slow fast 140 143 Gobo 16 shake slow fast 144 159 Gobo 17 shake slow fast 160 207 Gobo wheel scroll CW fast slow 208 255 Gobo wheel scroll CCW slow fast Channel Value Function CH10 000 007 Blackout 008 015 Open 016 131 Strobe slow fast 132 139 Open 140 ...

Page 28: ...gobo changing 103 119 Disable blackout whilst gobo changing 120 136 Enable blackout whilst pan tilt gobo colour change 137 153 Disable blackout whilst pan tilt gobo colour change 154 170 No function 171 187 Lamp On 188 204 Lamp Off 205 221 No function 222 238 Motor reset hold for 5 seconds 239 255 No function 18 channel mode cont Static gobos Open Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 G...

Page 29: ...l makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assi...

Page 30: ... adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal 3 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR male Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C DMX setup Termination reduces signal transmissi...

Page 31: ...ber of fixtures are connected a new power run will need to be started Please note Caution should be used when power linking other fixtures to the 9RE Beam as the power consumption of other fixtures will vary Fixtures fitted with lamps often require 2 3 times more current on startup these may require their own power source Please contact your local retailer to purchase these accessories Replacement...

Page 32: ...le harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally saf...

Reviews: