Inserting a new lamp:
1. Disconnect the fixture from the mains and allow it to cool for a minimum of 60 minutes.
2. Loosen the 2 screws (1) labelled A and B on the lamp cover and remove the lamp cover (2) to access
the lamp compartment.
3. Remove both Fastons (terminal connectors) (4) from the flat blades of the lamp base.
4. Holding the lamp by the ceramic base (5), gently slide the lamp left from under the metal latch and
pull outwards and right at the same time to release it from the spring clips (6).
5. Holding the new lamp by its ceramic base (5), gently inset the lamp into the lamp compartment with
the right side first to fit into the spring clips. (The Fastons should be facing down.)
Only use the recommended lamp. Damages caused by not following the guidelines outlined in this
manual are not subject to warranty. Please follow the lamp manufacturers notes.
Warning! Do not touch the lamp envelope with bare hands. Should this happen the bulb must be
cleaned with a cloth soaked in alcohol and dried once cleaned.
6. Slide both Fastons (4) onto the lamp ensuring the correct wires are attached to the correct Faston
(black on the left and red on the right).
7. Re-insert the lamp cover (2) and
tighten the 2 screws (1) labelled
A and B on the lamp cover.
8. Connect the fixture to the mains.
9. Reset the ‘Lamp Hours’ in the
fixtures menu.
(See page 13 ‘Lamp Time’ for
instructions on how to clear
the lamp hours.)
Changing the Lamp
DANGER!
Unplug the fixture from the mains before replacing the lamp!
Never operate this fixture
without the lamp!
Do not operate this fixture
without all external covers!
1
1
2
5
3
3
6
6
4
4