BA-en-3018-2006_KNH18
13
3.4 Charging bars suitable for connection
The following charging bars are suitable for connecting to the KNH18 high
voltage generator:
• Point charging bars R23ATR,
• Charging bars R130A/R131A,
• Charging bars R120/R121A (note voltage limitation according to Ope-
rating Instructions R120/R121A).
The KNHV3 distributor box, available as an optional extra, allows the user
to increase the number of bars connected. When using this option make
sure that the sum of the bar currents does not exceed 1.3 mA
.
Example:
current per meter of active bar length: 1 mA
Sum of active bar lengths: 1.3 m
=> maximum total current: 1.3 mA
Fig. 3:
Installing the
generator, the
distributor box and
the charging bars
1 = KNH18
2 = Distributor box
3 = High voltage cable
4 = Charging bars
Z
0
01
77
y
KNH
34
3
1
2
4