9. Dimensions

Available lengths of the bar IONSTAR RX3

Fig. 8:
IONSTAR RX3 
discharging bar

Z

0

00

62

y

GL

> 200

AB

B

A

AB = working width

A = frist tip

GL = total length

B = last tip

winding surface

reference code

total length max. working 

width

weight

IONSTAR RX3/S000848

848 mm

920 mm

5.6 kg

IONSTAR RX3/S001088

1088 mm

1160 mm

6.8 kg

IONSTAR RX3/S001328

1328 mm

1400 mm

8.0 kg

IONSTAR RX3/S001568

1568 mm

1640 mm

9.2 kg

IONSTAR RX3/S001808

1808 mm

1880 mm

10.4 kg

IONSTAR RX3/S002048

2048 mm

2120 mm

11.6 kg

IONSTAR RX3/S002288

2288 mm

2360 mm

12.8 kg

IONSTAR RX3/S002528

2528 mm

2600 mm

14.0 kg

IONSTAR RX3/S002768

2768 mm

2840 mm

15.2 kg

IONSTAR RX3/S003008

3008 mm

3080 mm

16.4 kg

Summary of Contents for IONSTAR RX3

Page 1: ...Operating Instructions IONSTAR RX3 Discharging Bar for 24 V DC BA en 2058 1808 RX3_re...

Page 2: ...2 BA en 2058 1808_IONSTAR RX3...

Page 3: ...erational safety 9 3 Installation and assembly 11 3 1 Assembling the discharging bar 11 3 2 Connecting supply voltage and connector 13 3 3 Ground connection 13 3 4 Connecting socket for function and f...

Page 4: ...4 BA en 2058 1808_IONSTAR RX3...

Page 5: ...wearing emission tips shockless no danger of electrical shock to personnel robust design function and fault monitoring with floating signal contacts automatic distance measurement with discharge opti...

Page 6: ...6 BA en 2058 1808_IONSTAR RX3...

Page 7: ...109988d_1 distance measurement depending on the version operating display LED connector supply voltage connector function and fault signals connection for application ground Fig 2 IONSTAR RX3 discharg...

Page 8: ...is symbol denotes the special conditions which must be observed when operating the system in explosion hazard areas as specified in the EX approvals 2 2 Contact protection The site of installation and...

Page 9: ...hich the IONSTAR RX3 is installed or if a conductive coating e g metallic inks is applied or printed the IONSTAR RX3 must be de energised Before carrying out repairs cleaning or maintenance work and b...

Page 10: ...ng notices must be dis played The operation of the bars can generate ozone The ozone concentra tion levels developing near the bars depend on many different factors such as site of installation bar cu...

Page 11: ...Evenly space the sliding nuts across the full length below 1 meter total length 2 per bar below 2 meters total length 3 per bar over 2 meters total length 4 per bar Warning For safety in operation pl...

Page 12: ...the machine environment i e no discharging against the idler roller A rough guideline No objects of conductive grounded material must be mounted within a minimum distance of 260 mm from the tip array...

Page 13: ...ected via the connector plug supplied Alternatively the optional power supply unit may be used To ensure that no voltage is supplied to the bars when the material web is at rest enabling the supply vo...

Page 14: ...als Warning Contact 1 to contact 2 COM open no Warning contact closed Malfunction Contact 3 to contact 2 COM open no malfunction contact closed No line voltage both contacts open Caution Contact 4 5 a...

Page 15: ...rvals are possible the discharging bar otherwise operates continuously The yellow LED signals warning messages LED off optimum working range LED flashing in 1 2 second cycles Distance current working...

Page 16: ...brush with soft plastic bristles Clean grease ink glue paper dust etc off the discharging bar and the distance detection using a suitable solvent benzine Do not soak the bars and the high voltage cabl...

Page 17: ...ce in the vicinity of bar or power supply units Clean bar see chapter Maintenance Check installation situation Loctate and rectify the source of interfe rance if necessary take measures to suppress in...

Page 18: ...if the operating and assembly instructions spe cified by Eltex have been observed The warranty period begins on the date of delivery In the event of defects occurring during the warranty period the u...

Page 19: ...ewing Bar element glass fibre reinforced plastic GRP Encapsulation material polyurethane Emission tips tungsten Installation material sliding nuts M6 Short circuit current tip max 0 45 mA Function and...

Page 20: ...ng width weight IONSTAR RX3 S000848 848 mm 920 mm 5 6 kg IONSTAR RX3 S001088 1088 mm 1160 mm 6 8 kg IONSTAR RX3 S001328 1328 mm 1400 mm 8 0 kg IONSTAR RX3 S001568 1568 mm 1640 mm 9 2 kg IONSTAR RX3 S0...

Page 21: ...se specify the article number when ordering Article Article No Power supply with mains cable 111114 Sliding nut M6 106251 Voltage supply connector 109536 Function and fault signal connector 109537 Vol...

Page 22: ...22 BA en 2058 1808_IONSTAR RX3...

Page 23: ......

Page 24: ...67 69 D 79576 Weil am Rhein Phone 49 0 76 21 79 05 230 Fax 49 0 76 21 79 05 330 eMail static control eltex com Internet www eltex com Eltex offices and agencies The addresses of all Eltex agencies can...

Reviews: